S&A Indutrial chiller expert12 years experience in chiller research, development, manufacture and sale
ROHSCEISO
Email: marketing@teyu.com.cnTel: +86-20-89301885
laser marking machine water chiller
Current location: HomeNews Center » News Center » Cases » Cold water machine is used for cooling the glass pipe 6 30W

Recommended Products

Chiller CW-6100
Chiller CW-6100
S&A chiller CW-6100 has 2 temperature control modes as constant temperature and intelligent temperature control mode. Generally speaking, the defaulted setting for the temperature controller is intelligent temperature control mode. Under intelligent temperature control mode, the water temperature will adjust itself according to the ambient temperature. However, under constant temperature control mode, users can adjust the water temperature manually.
Chiller CWFL-800
Chiller CWFL-800
S&A CWFL-800 water chillers, specially designed for cooling fiber lasers, are characterized by dual circulating refrigeration system and dual temperature control system. The CWFL series water chillers are so multi-functional that the laser device and the QBH connector/optics can be cooled by the low temperature control system and the high temperature control system respectively at the same time, which can greatly reduce the generation of the condensed water and save cost.
Chiller CWFL-2000
Chiller CWFL-2000
S&A CWFL-2000 water chillers, specially designed for cooling fiber lasers, are characterized by dual circulating refrigeration system and dual temperature control system. The CWFL series water chillers are so multi-functional that the laser device and the QBH connector/optics can be cooled by the low temperature control system and the high temperature control system respectively at the same time, which can greatly reduce the generation of the condensed water and save cost.
Chiller CW-6200
Chiller CW-6200
S&A chiller CW-6200 has 2 temperature control modes as constant temperature and intelligent temperature control mode. Generally speaking, the defaulted setting for the temperature controller is intelligent temperature control mode. Under intelligent temperature control mode, the water temperature will adjust itself according to the ambient temperature. However, under constant temperature control mode, users can adjust the water temperature manually.
Chiller CW-5200
Chiller CW-5200
S&A CW-5200 is refrigeration type industrial water chiller of 1400W cooling capacity. It’s mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. The water temperature is able to be adjusted. There are 2 specifications as 1 water outlet/inlet and dual water outlet/inlet, applicable to cool single laser glass tube.
Chiller CWFL-1500
Chiller CWFL-1500
S&A CWFL-1500 water chillers, specially designed for cooling fiber lasers, are characterized by dual circulating refrigeration system and dual temperature control system. The CWFL series water chillers are so multi-functional that the laser device and the QBH connector/optics can be cooled by the low temperature control system and the high temperature control system respectively at the same time, which can greatly reduce the generation of the condensed water and save cost.
Chiller CW-5000
Chiller CW-5000
S&A CW-5000 is refrigeration type industrial water chiller of 800W cooling capacity. It’s mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. The water temperature is able to be adjusted. There is 1 water outlet and an inlet, applicable to cool single laser glass tube.
Chiller CW-6000
Chiller CW-6000
S&A chiller CW-6000 has 2 temperature control modes as constant temperature and intelligent temperature control mode. Generally speaking, the defaulted setting for the temperature controller is intelligent temperature control mode. Under intelligent temperature control mode, the water temperature will adjust itself according to the ambient temperature. However, under constant temperature control mode, users can adjust the water temperature manually.

Top articles

Latest articles

Your browsing history

    Loading...

Cold water machine is used for cooling the glass pipe 6 30W

Categories: CasesStars: 3Stars Visit: - Release time: 2013-11-30 14:25:00
RSS subscription Font size:【 Large Middle Small Source: Editor: Author:

In October 18th, received a Beijing customers to call to consult the CW-5202AG cold water machine, the customer said a peer using our CW-5202AG chiller cooling of 4 serial 30W glass tube to see at the same time, ask if you can at the same time, cooling of 6 serial 30W glass tube.
In fact, 4 glass tubes in series with the cooling water, cold water machine through a glass tube, water resistance will increase by recursion, heat continuously mixed superposition, temperature variation between pipe and pipe parallel to the glass tube, instant damage, and the series can also lead to water cooling is not uniform, as to extend the service life of 4 glass tube, glass tube that is in parallel connection with water cooling machine, special domain based on user cooling glass tube number, outlet custom multiple joints.
CW-5202AG cold water cooling capacity up to 1400W, can also cool 4 series 30W glass tube, but in order to protect the laser, 4 glass tubes using parallel cooling way is the best.
Advantages and disadvantages of the way I truthfully the series and parallel cooling analysis to customers in Beijing, but for the convenience of customers, adhere to the series, therefore, I suggest that customers can use series by increasing glass cooling tube
As for the test results to customers in Beijing, and the next time the solution.