S&A Industrial chiller expert16 years experience in chiller research, development, manufacture and sale
ROHSCEISOREACH
Email:marketing@teyu.com.cnTel:+86-20-89301885
laser marking machine water chiller
Current location: HomeNews Center » News Center » FAQ » How to deal with high temperature alarm of water chiller which cools stainless steel engraving machine?

Recommended Products

Water chiller CWFL-2000 for 2000W fiber laser
Water chiller CWFL-2000 for 2000W fiber laser
S&A compressor refrigeration industrial water chiller CWFL-2000 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd.CWFL-2000 chiller is special applied for cooling 2000W fiber laser.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Water chiller CWFL-1500 for 1500W fiber laser
Water chiller CWFL-1500 for 1500W fiber laser
S&A refrigeration industrial water chiller CWFL-1500 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd. CWFL-1500 chiller is special applied for cooling 1500W fiber laser.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Water chiller CWFL-3000 for 3000W fiber laser
Water chiller CWFL-3000 for 3000W fiber laser
S&A compressor refrigeration industrial water chiller CWFL-3000 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd.CWFL-3000 chiller is special applied for cooling 3000W fiber laser.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Water chiller CWFL-4000 for 4000W fiber laser
Water chiller CWFL-4000 for 4000W fiber laser
S&A high power refrigeration industrial water chiller CWFL-4000 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd. CWFL-4000 chiller is special applied for cooling 4000W fiber laser.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Chiller CW-5200 1400W cooling capacity
Chiller CW-5200 1400W cooling capacity
S&A CW-5200 is refrigeration type industrial water chiller of 1400W cooling capacity. It’s mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. The water temperature is able to be adjusted. There are 2 specifications as 1 water outlet/inlet and dual water outlet/inlet, applicable to cool single laser glass tube.
Water chiller CWFL-12000 for 12000W fiber laser
Water chiller CWFL-12000 for 12000W fiber laser
S&A high power refrigeration industrial water chiller CWFL-12000 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd. S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Water chiller CWFL-8000 for 8000W fiber laser
Water chiller CWFL-8000 for 8000W fiber laser
S&A high power refrigeration industrial water chiller CWFL-8000 with dual temp control function is produced by Guangzhou Teyu Electromechanical Co., Ltd.S&A CWFL series chiller is special for cooling Raycus,IPG,Max,nLIGHT,trumpf,Rofin and SPI fiber laser.
Chiller CW-6300 8500W cooling capacity
Chiller CW-6300 8500W cooling capacity
S&A CW-6300 series is high-precision compression refrigeration water chiller,with intelligent temperature control,completed configuration,perfect protection and alarm system. Features 1. 8500W cooling capacity; optional environmental refrigerant; 2.±1? precisely temperature control;

Top articles

Latest articles

Your browsing history

    Loading...

How to deal with high temperature alarm of water chiller which cools stainless steel engraving machine?

Categories: FAQStars: 3Stars Visit: - Release time: 2018-06-28 10:00:00
RSS subscription Font size:【 Large Middle Small Source: www.teyuchiller.com Editor: S&A chiller Author: S&A

Water chiller which cools stainless steel engraving machine is also called industrial water chiller. Its high temperature alarm is triggered during operation mainly due to the following reasons:

 
1.The equipped water chiller doesn’t have enough cooling capacity. This problem may not be obvious in winter, but in summer as the ambient temperature rises, your water chiller can’t cool the equipment efficiently. It is suggested to use the water chiller with higher cooling capacity.
2.The equipped water chiller is dusty and the heat can’t release very quickly. It is suggested to clean the condenser by air gun and unpick and wash the dust gauze regularly.
 
In addition, please make sure the good ventilation of the air inlet and outlet of the water chiller and put it in an environment with the ambient temperature below 40 degree Celsius. The above suggestions help reduce the malfunction of the water chiller and extend its working life.
 
 
In respect of production, S&A has invested the production equipment of more than one million RMB, ensuring the quality of a series of processes from the core components (condenser) of industrial chiller to the welding of sheet metal; in respect of logistics, S&A has set up logistics warehouses in the main cities of China, having greatly reduced the damage due to the long-distance logistics of the goods, and improved transport efficiency; in respect of after-sales service, the warranty period is two years.
 
For more cases of S&A industrial water chiller cooling engraving machine, please click http://www.teyuchiller.com/product/ 
 
water chiller