S&A Industrial chiller expert16 years experience in chiller research, development, manufacture and sale
ROHSCEISOREACH
Email:marketing@teyu.com.cnTel:+86-20-89301885
laser marking machine water chiller
Current location: HomeS&A News Center » Hot News
S&A chillers are shown on 2016 Guangzhou international Signs Exhibiton[ 07-28 21:46 ]
As the standard air water cooling system of fiber laser cutting machines and UV printers, S&A industrial chillers are shown on 2016 Guangzhou international Signs Exhibiton along with them.
what is the lowest temperature you can drive the chiller CW-5200 stably?[ 07-25 22:11 ]
A customer is from a University and would like to know more information regarding your chiller CW-5200: what is the lowest temperature it can drive the chiller stably?
Thermoformers customer reflects S&A chiller works great[ 07-21 05:18 ]
Thermoformers customer from U.S.A reflects S&A air cooled water chiller model CW-5200 works great and now he needs to purchases 2 pcs S&A air cooled water chiller CW-5200.
When the air cooled chiller turned on but unelectrified[ 07-15 04:53 ]
Now, I will show you the troubleshooting When the machine turned on but unelectrified The failure cause: Power cord is not plugged in place or fuse burnt-out
Czech customer purchases S&A chiller to cool 600-800W laser[ 07-12 22:07 ]
A customer from Czech is intended to buy S&A chiller for cooling 600-800W laser machine. The requirements listed below: 1. The target water temperature is 10-30℃. 2. Water flow is 5L/min. 3. Voltage is 230V.
S&A air cooled chillers are shown on AD exhibition along with laser cutter[ 07-08 02:03 ]
S&A air cooled chillers are shown on Shanghai intl four new advertising & sign exhibition along with customer' s laser cutting machine.
UVLED source customer reflects the chiller occurrs water flow alarm[ 06-30 04:19 ]
Tang has bought S&A chiller CW-5200 to cool 120W and 600W UVLED source, but it occurred flow alarm after connecting with his equipment. As a result, he contacted S&A after-sales dept. at the first time.
Laser customer buy a copy produce of S&A chiller[ 06-27 23:23 ]
Two days ago, a customer placed an order for S&A chiller CW-5200 on alibabe. The customer is a laser manufacturer and purchased chiller CW-5200 of 1400W cooling capacity for cooling 130W glass laser tube.
When the S&A chiller display E5 alarm, pls follow me[ 06-22 21:38 ]
E5 means water temperature sensor failure alarm When alarm occurs The error code and the temperature will be alternately displayed The alarm sound could be suspended by pressing any button
How to slove E4 alarm of S&A water chiller CW-5200[ 06-22 21:31 ]
Hello, I am Mark from S&A chiller company Now I show you the troubleshooting of E4 alarm of S&A chiller CW-5200 E4 means room temperature sensor failure alarm When alarm occurs The error code and the temperature will be alternately displayed The alarm sound could be suspended by pressing any button
The troubleshooting of E3 alarm of S&A water chiller CW-5200[ 06-22 04:03 ]
E3 means over low water temperature alarm When alarm occurs The error code and the temperature will be alternately displayed The alarm sound could be suspended by pressing any button Under low ambient temperature( e.g. in winter)
Moldova laser customer falls in love with S&A chiller at first sight[ 06-20 03:42 ]
S&A chiller was shown on the CIFM exhibition along with customer laser. A Moldova fell in love with S&A chiller at first sight. The customer intend s to buy S&A chiller to cool 2 units of 90W laser tubes
S&A laser chillers were shown on the 21st Beijing Essen welding&cutting fair[ 06-15 22:49 ]
As the water cooling system of laser machine, S&A laser chillers were shown on the 21st Beijing Essen welding&cutting fair along with laser welding & cutting machine.
The troubleshooting of E2 alarm of S&A chiller CW-5200[ 06-15 04:13 ]
E2 means over high water temperature alarm When alarm occurs,the error code and the temperature will be alternately displayed The alarm sound could be suspended by pressing any button
S&A chillers are shown on customer website with the laser photoplotter.[ 06-14 01:51 ]
There is a laser photoplotter customer from Poland who has purchased S&A water cooler CW-3000, refrigeration chiller CW-5000,CW-5200and CW-6300 . S&A chillers are shown on his website with the laser photoplotter.
What temperature range will the S&A chiller work within?[ 06-13 03:30 ]
S&A chillers work within 5℃-35℃, the controllable lowest temperature depends on the heat load of the cooled machine and the cooling capacity of chiller. S&A suggest the best running temp is 20℃-30℃. S&A chiller's warranty is 24 months. Thanks for using S&A chiller.
An Australia customer knows S&A chiller on Food Chinanet website[ 06-01 22:25 ]
An Australia customer knows S&A chiller on Food Chinanet website, after visiting the technical parameter of chiller, he contacts S&A directly. The customer said he is impressed with the design of S&A chiller, which will match their machine.
The troubleshooting of E1 alarm of S&A chiller CW-5200[ 05-25 04:58 ]
E1 means over high room temperature, when the chiller display E1 alarm, the E1 code and water temperature will be alternately displayed Press any button, the alarm sound could be suspended.
Total number of records:516 | Pages:29  <...78910111213141516...>  

Contact S&A

TEL: +86-20-89301885

FAX: +86-20-84309967

SKYPE: teyuchiller

marketing@teyu.com.cn

techsupport@teyu.com.cn