Fiber Laser Chiller
VR
Product Introduction

Model: RMFL-1000

Machine Size: 75 X 48 X 45cm  (L X W X H)

Warranty: 2 years

Standard: CE, REACH and RoHS

Product Parameters
ModelRMFL-1000
VoltageAC 1P 220-240V
Frequency50Hz
Current2.5~11.4A
Machine power4.54kW

Compressor power

1.16kW
1.58HP


Nominal cooling capacity

11604Btu/h
3.4kW
2923Kcal/h
RefrigerantR-410a
Refrigerant charge580g
Precision±0.5℃
ReducerCapillary
Tank capacity12L
Inlet and outletRp1/2" + Rp1/2"
Pump power0.55kW
Max. pump lift36M
Max. pump flow2L/min+>15L/min
N.W.63Kgs
G.W.72Kgs
Dimension75 X 48 X 45cm  (L X W X H)
Package dimension88 X 58 X 63cm  (L X W X H)

The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

Product Features

* Rack mount design

* Dual cooling circuit

* Active cooling

* Temperature stability: ±0.5°C

* Temperature control range: 5°C ~35°C

* Refrigerant: R-410a

* Intelligent digital control panel

* Integrated alarm functions

* Front mounted water fill port and drain port

* Integrated front handles

* High level of flexibility and mobility

Optional Items

              

 Heater


               

Filter


              

 US standard plug / EN standard plug


Product Details
                                       

Dual temperature control


Two intelligent temperature controllers are installed. One is for controlling the temperature of the fiber laser and the other is for controlling the optics.

                                       

Front mounted water fill port and drain port


The water fill port and drain port are mounted in the front for easy water filling and draining.

                                       

Integrated front handles


The front-mounted handles help move the chiller very easily.

Certificate
Product Working Principle

FAQ
Is S&A Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
What is the ideal room temperature for the chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (techsupport@teyu.com.cn) first.
Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

If You Have More Questions, Write To Us

Just leave your email or phone number on the contact form so we can provide you with more services!

Choose a different language
English English العربية العربية Deutsch Deutsch Español Español français français italiano italiano 日本語 日本語 한국어 한국어 Português Português русский русский 简体中文 简体中文 繁體中文 繁體中文 Afrikaans Afrikaans አማርኛ አማርኛ Azərbaycan Azərbaycan Беларуская Беларуская български български বাংলা বাংলা Bosanski Bosanski Català Català Sugbuanon Sugbuanon Corsu Corsu čeština čeština Cymraeg Cymraeg dansk dansk Ελληνικά Ελληνικά Esperanto Esperanto Eesti Eesti Euskara Euskara فارسی فارسی Suomi Suomi Frysk Frysk Gaeilgenah Gaeilgenah Gàidhlig Gàidhlig Galego Galego ગુજરાતી ગુજરાતી Hausa Hausa Ōlelo Hawaiʻi Ōlelo Hawaiʻi हिन्दी हिन्दी Hmong Hmong Hrvatski Hrvatski Kreyòl ayisyen Kreyòl ayisyen Magyar Magyar հայերեն հայերեն bahasa Indonesia bahasa Indonesia Igbo Igbo Íslenska Íslenska עִברִית עִברִית Basa Jawa Basa Jawa ქართველი ქართველი Қазақ Тілі Қазақ Тілі ខ្មែរ ខ្មែរ ಕನ್ನಡ ಕನ್ನಡ Kurdî (Kurmancî) Kurdî (Kurmancî) Кыргызча Кыргызча Latin Latin Lëtzebuergesch Lëtzebuergesch ລາວ ລາວ lietuvių lietuvių latviešu valoda‎ latviešu valoda‎ Malagasy Malagasy Maori Maori Македонски Македонски മലയാളം മലയാളം Монгол Монгол मराठी मराठी Bahasa Melayu Bahasa Melayu Maltese Maltese ဗမာ ဗမာ नेपाली नेपाली Nederlands Nederlands norsk norsk Chicheŵa Chicheŵa ਪੰਜਾਬੀ ਪੰਜਾਬੀ Polski Polski پښتو پښتو Română Română سنڌي سنڌي සිංහල සිංහල Slovenčina Slovenčina Slovenščina Slovenščina Faasamoa Faasamoa Shona Shona Af Soomaali Af Soomaali Shqip Shqip Српски Српски Sesotho Sesotho Sundanese Sundanese svenska svenska Kiswahili Kiswahili தமிழ் தமிழ் తెలుగు తెలుగు Точики Точики ภาษาไทย ภาษาไทย Pilipino Pilipino Türkçe Türkçe Українська Українська اردو اردو O'zbek O'zbek Tiếng Việt Tiếng Việt Xhosa Xhosa יידיש יידיש èdè Yorùbá èdè Yorùbá Zulu Zulu
Current language:English