loading

UL-Certified Chiller CW-5200TI

With 0.3℃ Precision and 1770W/2080W Cooling Capacity


TEYU S&A Industrial Chiller CW-5200TI, certified with the UL mark, meets rigorous safety standards in both the U.S. and Canada. This certification, along with additional CE, RoHS, and Reach approvals, ensures high safety and compliance. With ±0.3℃ temperature stability and up to 2080W cooling capacity, CW-5200TI provides precise cooling for critical operations. Integrated alarm functions and a two-year warranty further enhance safety and reliability, while the user-friendly interface offers clear operational feedback.


Versatile in its applications, industrial chiller CW-5200TI efficiently cools a range of equipment, including CO2 laser machines, CNC machine tools, packaging machinery, and welding machines across various industries. 50Hz/60Hz dual-frequency ensures compatibility with different systems, and its compact and portable design offers quiet operation. Intelligent temperature control modes ensure optimal performance, making the chiller CW-5200TI a reliable and efficient solution for industrial cooling needs.

keine Daten

Product characteristics

keine Daten

Product parameters

Modell

CW-5200TI

Stromspannung

AC 1P 220~240V

Aktuell

0.8~4.5A

Frequenz

50/60Hz

Kompressorkraft 0.5/0.57KW

Max. Stromverbrauch

0.84KW

0.67/0.76HP Pumpenleistung 0.11KW
Nominale Kühlkapazität 6039/7096BTU/h Max. Pumpendruck 2.5Bar
1.77/2.08KW Max. Pumpenfluss 19l/min
1521/1788kcal/h Kältemittel R-134a
Reduzierer Kapillar Präzision ±0.3℃
Einlass und Ausgang OD 10 mm Stachelstecker Tankkapazität 6L
N.W. 27kg Dimension 58x29x47cm (l x w x h)
G.W. 30kg Paketdimension 65x36x51cm (l x w x h)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.
keine Daten

Produktdetails

Benutzerfreundliches Bedienfeld
Der Temperaturregler bietet eine hohe Präzisionstemperaturregelung von ± 0,3 ° C und zwei benutzerfeindliche Temperaturregelmodi - konstanter und intelligenter Kontrollmodus
Premium -Heizung
Die eingebaute Heizung in einem Kühler sorgt dafür
Leicht zu lesendem Wasserstandsindikator
Der Wasserstandsindikator hat 3 Farbbereiche:
Gelbe Fläche - Hochwasserspiegel.
Grünfläche - Normaler Wasserstand.
Roter Fläche - niedriger Wasserstand
Bemerkenswerter Statuslicht
Es gibt 2 Statuslichter - rotes Licht und grünes Licht.
Rotlicht - Alarm, auf Fehler prüfen.
Grünes Licht - normaler Betrieb
keine Daten

Certificate

UL-zertifizierter Chiller CW-5200Ti

Working principle

UL-zertifizierter Chiller CW-5200Ti

Lüftungsabstand

UL-zertifizierter Chiller CW-5200Ti

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Heim         Produkte           SGS & UL-Kühler         Kühllösung         Unternehmen         Ressource         Nachhaltigkeit
Copyright © 2025 TEYU S&Ein Chiller | Sitemap     Datenschutzrichtlinie
Kontaktiere uns
email
Wenden Sie sich an den Kundendienst
Kontaktiere uns
email
stornieren
Customer service
detect