loading

UL-Certified Chiller CW-5200TI

With 0.3℃ Precision and 1770W/2080W Cooling Capacity


TEYU S&A Industrial Chiller CW-5200TI, certified with the UL mark, meets rigorous safety standards in both the U.S. and Canada. This certification, along with additional CE, RoHS, and Reach approvals, ensures high safety and compliance. With ±0.3℃ temperature stability and up to 2080W cooling capacity, CW-5200TI provides precise cooling for critical operations. Integrated alarm functions and a two-year warranty further enhance safety and reliability, while the user-friendly interface offers clear operational feedback.


Versatile in its applications, industrial chiller CW-5200TI efficiently cools a range of equipment, including CO2 laser machines, CNC machine tools, packaging machinery, and welding machines across various industries. 50Hz/60Hz dual-frequency ensures compatibility with different systems, and its compact and portable design offers quiet operation. Intelligent temperature control modes ensure optimal performance, making the chiller CW-5200TI a reliable and efficient solution for industrial cooling needs.

no data

Product characteristics

no data

Product parameters

Model

CW-5200TI

Voltage

AC 1P 220~240V

Current

0.8~4.5A

Frequency

50/60Hz

Compressor power 0.5/0.57kW

Max. power consumption

0.84kW

0.67/0.76HP Pump power 0.11kW
Nominal cooling capacity 6039/7096Btu/h Max. pump pressure 2.5bar
1.77/2.08kW Max. pump flow 19L/min
1521/1788Kcal/h Refrigerant R-134a
Reducer Capillary Precision ±0.3℃
Inlet and outlet OD 10mm Barbed connector Tank capacity 6L
N.W. 27Kg Dimension 58X29X47cm (L X W X H)
G.W. 30Kg Package dimension 65X36X51cm (L X W X H)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.
no data

Product Details

User-friendly control panel
The temperature controller offers high precision temperature control of ±0.3°C and two user-adjustable temperature control modes - constant and intelligent control mode.
Premium heater
The built-in heater in a chiller ensures consistent temperature control, improving efficiency and preventing freezing in cold environments.
Easy-to-read water level indicator
The water level indicator has 3 color areas:
Yellow area - high water level.
Green area - normal water level.
Red area - low water level.
Noticeable status light
There are 2 status lights - red light and green light.
Red light - alarm, check for faults.
Green light - normal operation.
no data

Certificate

UL-Certified Chiller CW-5200TI

Working principle

UL-Certified Chiller CW-5200TI

Ventilation Distance

UL-Certified Chiller CW-5200TI

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
Contact us
email
Contact customer service
Contact us
email
cancel
Customer service
detect