loading
Lingua
7U-8U Rack Mount Chiller RMUP-500P pro Ultrafast et UV Laser Cooling
7U-8U Rack Mount Chiller RMUP-500P pro Ultrafast et UV Laser Cooling
7U-8U Rack Mount Chiller RMUP-500P pro Ultrafast et UV Laser Cooling
7U-8U Rack Mount Chiller RMUP-500P pro Ultrafast et UV Laser Cooling
7U-8U Rack Mount Chiller RMUP-500P pro Ultrafast et UV Laser Cooling
7U-8U Rack Mount Chiller RMUP-500P pro Ultrafast et UV Laser Cooling
7U-8U Rack Mount Chiller RMUP-500P pro Ultrafast et UV Laser Cooling
7U-8U Rack Mount Chiller RMUP-500P pro Ultrafast et UV Laser Cooling

Refrigeratorium 7U-8U in armario positum RMUP-500P ad refrigerationem ultravelocem et lasericam UV

7U-8U Refrigeratorium Montatum in Rack RMUP-500P Ad usus lasericos ultraveloces et UV ubi praecisio maximi momenti est fabricatum est. Stabilitatem temperaturae ±0.1℃ et subsidium potentiae dualis frequentiae (50/60Hz, 220–240V) offerens, eventus constantes et operationem fidam per systemata potentiae globalia praestat.

Designatio eius 19-unciarum in armario posita efficientiam spatii laboratorium amplificat dum refrigerationem stabilem praebet laseribus ultravelocibus et UV 10-20W. Operatio quieta et vibratio humilis opticam sensibilem custodiunt, dum filtrum 5-micron qualitatem aquae emendat ad vitam systematis extendendam. Cum connexione RS-485 ModBus, usores monitorio in tempore reali et imperio remoto fruuntur, quod solutionem idealem reddit ad micromachinationem laseris ultravelocem, fabricationem instrumentorum medicorum UV, et lithographiam semiconductorum.

5.0
design customization

    Me paenitet ...!

    productum sine notitia.

    ad homepage
    Introductio Producti
     Refrigeratorium 7U in armario positum RMUP-500TNP ad refrigerationem ultravelocem et lasericam UV

    Exemplar: RMUP-500P

    Magnitudo Machinae: 67 x 48 x 33 cm (L × L × A) 7U, 67 x 48 x 37 cm (L × L × A) 8U

    Garantia: biennium

    Norma: CE, REACH et RoHS

    Parametri Producti
    Modellum RMUP-500TNPTYRMUP-500DNPTYRMUP-500TNP8UTY
    Tensio electricaAC 1P 220-240VAC 1P 220~240V
    Frequentia 50Hz 60Hz 50/60Hz
    Currens 1~7.7A1.8~12A1.2~7.5A
    Maxima energiae consumptio 1.42kW/1.52kW 1.43kW 1.38kW/1.47
    Potentia compressoris 0.6kW/0.7kW 0.58 kW 0.57 kW/0.66 kW
    0.82HP/0.95HP0.79HP0.78HP/0.9HP
    Capacitas refrigerandi nominalis 4094 Btu/h
    1.2kW
    1032Kcal/h
    Refrigerans R-407cR-32 R-1234yf
    Praecisio ±0.1℃
    Reductor Capillaris
    Vis antliae 0.26kW 0.3kW 0.26kW
    Capacitas cisternae7L8L
    Ingressus et exitus Coniunctor celer Φ10
    Pressio maxima antliae Tres vectes 3.5 vectes Tres vectes
    Fluxus maximus antliae 60 L/min
    N.W. XXXV chiliogrammata
    G.W. 39 kg
    Dimensio 67 x 48 x 33 cm (L × A × A) 7U 67 x 48 x 37 cm (L × A × A) 8U
    Dimensio sarcinae 74 57 50 cm (L W H) 74 57 54 cm (L W H)

    Fluxus electricus operandi sub variis condicionibus laboris variari potest. Informationes supradictae ad solam referentiam sunt. Quaeso, secundum productum revera traditum, accommoda.

    Proprietates Producti

    Functiones intelligentes

    * Detectio aquae humilis in cisterna

    * Detectio fluxus aquae humilis

    * Temperatura aquae supra detegendum

    * Calefactio aquae refrigerantis ad temperaturam ambientis humilem

    Ostentatio auto-probationis

    * Duodecim genera codicum alarmis

    Facilis cura ordinaria

    * Cura sine instrumentis cribri filtratorii pulveris resistentis

    * Filtrum aquae celeriter substituibile, quod optio praebetur

    Functio communicationis

    * Protocollo RS485 Modbus RTU instructum

    Res Optionales

    Calefactor

     

    Filtrum

     

    Obturaculum normae Americanae / obturaculum normae EN

     

    Singula Producti
     Refrigeratorium 7U in armario positum RMUP-500TNP, regulator temperaturae digitalis

    Regulator temperaturae digitalis

     

    Regulator temperaturae T-801B praecisionem magnam moderationis temperaturae ±0.1°C praebet.

     Refrigeratorium 7U in armario collocandum RMUP-500TNP, porta impletionis aquae et porta exhauriendi anterioris.

    Ostium impletionis aquae et ostium exhauritionis anterioris positi

     

    Ostium impletionis aquae et ostium exhauriendi in parte anteriore positi sunt ad facilem aquae impletionem et exhauritionem.

     Refrigeratorium 7U in armario collocandum RMUP-500TNP, portus communicationis Modbus RS485

    Portus communicationis Modbus RS485

     

    Portus communicationis RS485 communicationem cum systemate laserico permittit.
    Certificatum
     Refrigeratorium 7U in Rack Mounting Chiller RMUP-500TNP Certificatum
    Principium Operationis Producti

     Principium Operationis Producti RMUP-500TNP pro Refrigeratore 7U pro Rack Mounting

    FAQ
    Estne TEYU Chiller societas mercatoria an fabricator?
    Fabricatores professionales refrigeratorum industrialium ab anno MMII sumus.
    Quaenam aqua in refrigeratore aquae industriali adhibenda commendatur?
    Aqua optima debet esse aqua deionizata, aqua destillata, vel aqua purificata.
    Quam saepe aquam mutare debeo?
    Generaliter loquendo, frequentia mutationis aquae est tres menses. Etiam pendere potest ex vera condicione laboris refrigeratorum aquae recirculantis. Exempli gratia, si condicio laboris nimis inferior est, frequentia mutationis commendatur ut sit unus mensis vel brevior.
    Quae est temperatura cubiculi optima pro refrigeratore aquae?
    Locus ubi refrigerator aquae industrialis laborat bene ventilatus esse debet, et temperatura cubiculi non plus quam 45 gradus Celsius excedat.
    Quomodo refrigeratorium meum ne congelescat prohibeam?
    Usoribus qui in regionibus altae latitudinis, praesertim hieme, habitant, saepe problema aquae congelatae patitur. Ne refrigerator congelescat, calefactorem optionalem vel anticongelans in refrigeratore addere possunt. Ad usum anticongelantis accuratius, suadetur ut turmam auxilii clientium nostram contactes.service@teyuchiller.com ) primum.

    Adsumus tibi cum nobis opus est.

    Quaeso, formam imple ut nobiscum communicare possis, et libenter te adiuvabimus.

    Producta Similia
    absque notitia
    Domus   |     Producta       |     Refrigeratorium SGS et UL       |     Solutio Refrigerans     |     Societas      |    Opus       |      Sustentabilitas
    Ius proprietatis © 2026 TEYU S&A Refrigeratorium | Index situs Consilium de secreto
    Nobis loquere
    email
    Contact Customer Service
    Nobis loquere
    email
    inrita
    Customer service
    detect