loading
Language
7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling 1
7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling 2
7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling 3
7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling 4
7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling 1
7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling 2
7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling 3
7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling 4

7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling

7U Rack Mount Chiller RMUP-500TNP is engineered for ultrafast and UV laser applications where precision is critical. Offering ±0.1℃ temperature stability and dual-frequency power support (50/60Hz, 220–240V), it guarantees consistent results and reliable operation across global power systems.

Its 19-inch rack-mounted design maximizes lab space efficiency while delivering stable cooling for 10W–20W ultrafast and UV lasers. Quiet operation and low vibration safeguard sensitive optics, while a 5-micron filter improves water quality to extend system life. With RS-485 ModBus connectivity, users benefit from real-time monitoring and remote control, making it an ideal solution for ultrafast laser micromachining, UV medical device manufacturing, and semiconductor lithography.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    7U Rack Mount Chiller RMUP-500TNP for Ultrafast and UV Laser Cooling

    Model: RMUP-500TNP

    Machine Size: 67X48X33cm (L X W X H) 7U

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    Model RMUP-500TNPTY
    Voltage AC 1P 220-240V
    Frequency 50Hz 60Hz
    Current 1.2~5.7A 1.2~5.7A
    Max. power consumption 2.05kW 2.95kW
    Compressor power 1.73kW 2.09kW
    2.32HP 2.8HP
    Nominal cooling capacity 4229Btu/h
    1.24kW
    1064Kcal/h
    Refrigerant R-407c
    Precision ±0.1℃
    Reducer Capillary
    Pump power 0.26kW
    Tank capacity 7L
    Inlet and outlet Rp1/2”
    Max. pump pressure 3bar
    Max. pump flow 57L/min
    N.W. 35Kg
    G.W. 39Kg
    Dimension 67x48x33cm (L X W X H) 7U
    Package dimension 74x57x50cm (L X W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    Intelligent functions

    * Low tank water level detecting

    * Low water flow rate detecting

    * Over water temperature detecting

    * Heating of the coolant water at low ambient temperature

    Self-check display

    * 12 types of alarm codes

    Easy routine maintenance

    * Toolless maintenance of dustproof filter screen

    * Quick-replaceable optional water filter

    Communication function

    * Equipped with RS485 Modbus RTU protocol

    Optional Items

                  

     Heater

     

                   

    Filter

     

                  

     US standard plug / EN standard plug

     

    Product Details
    7U Rack Mount Chiller RMUP-500TNP Digital temperature controller

                                            Digital temperature controller

     

    The T-801B temperature controller offers high precision temperature control of ±0.1°C. 

    7U Rack Mount Chiller RMUP-500TNP Front mounted water fill port and drain port

                                            Front mounted water fill port and drain port

     

    The water fill port and drain port are mounted in the front for easy water filling and draining.

    7U Rack Mount Chiller RMUP-500TNP Modbus RS485 communication port

                                            Modbus RS485 communication port

     

    The RS485 communication port enables communication with the laser system.
    Certificate
    7U Rack Mount Chiller RMUP-500TNP Certificate
    Product Working Principle

    7U Rack Mount Chiller RMUP-500TNP Product Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the water chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect