Isifudumezi
Hluza
Iplagi esemgangathweni yase-US / iplagi ye-EN eqhelekileyo
Rack Mount chiller I-RMUP-500 ine-design ye-rack ye-6U ye-rack kwaye ifanelekile kwi-10W-15W ye-UV laser kunye ne-ultrafast laser applications. Inika ukupholisa okuchane kakhulu kwe-±0.1°C uzinzo ngobuchwepheshe bolawulo lwe-PID. Ifakwe kwi-rack ye-6U, le nkqubo yokupholisa amanzi kwimizi-mveliso ivumela ukupakishwa kwesixhobo esihambelanayo, ebonisa izinga eliphezulu lokuguquguquka kunye nokuhamba. Amandla efriji anokufikelela kwi-650W kwaye umbane okhoyo ngu-220V. Ukuhlolwa komgangatho wamanzi kufakwe ngaphambili kunye nezibonakaliso ezicingayo. Ubushushu bamanzi bunokusetwa phakathi kwe-5°C kunye ne-35°C kunye nemowudi yobushushu obungaguqukiyo okanye indlela yokulawula ubushushu obukrelekrele bokhetho.
Umzekelo: RMUP-500
Ubungakanani bomatshini: 49X48X26cm (L X W X H) 6U
Iwaranti: iminyaka emi-2
Umgangatho: CE, REACH kunye neRoHS
Umzekelo | I-RMUP-500 | |
I-RMUP-500AI | I-RMUP-500BI | |
I-Voltage | AC 1P 220-240V | AC 1P 220-240V |
Ukuphindaphinda | 50Hz | 60Hz |
Okwangoku | 0.6~5.2A | 0.6~5.2A |
Max. Ukutya umbane | 0.98kW | 1kW |
Amandla eCompressor | 0.32kW | 0.35kW |
0.44HP | 0.46HP | |
Umthamo wokupholisa oqhelekileyo | 2217Btu/h | |
0.65kW | ||
558Kcal/h | ||
Isikhenkcisi | R-134a | |
Ukuchaneka | ±0.1℃ | |
Isinciphisi | I-Capillary | |
Impompo amandla | 0.09kW | |
Umthamo wetanki | 5.5L | |
Ukungena kunye nokuphuma | Rp1/2” | |
Max. uxinzelelo lwempompo | 2.5 ibha | |
Max. ukuhamba kwempompo | 15L/min | |
N.W. | 21Kg | |
G.W. | 24Kg | |
Ubungakanani | 49 X 48 X 26cm (L X W X H) 6U | |
Ubungakanani bephakheji | 59 X 53 X 34cm (L X W X H) |
Umsebenzi wangoku unokwahluka phantsi kweemeko ezahlukeneyo zokusebenza. Ezi nkcukacha zingentla zenzelwe ireferensi kuphela. Nceda uxhomekeke kweyona mveliso ithunyelweyo.
Imisebenzi ekrelekrele
• Ukubona umgangatho wamanzi wetanki ephantsi
• Ukubona umyinge wokuhamba kwamanzi aphantsi
* Ukubona ubushushu bamanzi ngaphezulu kwamanzi
• Ukufudunyezwa kwamanzi okupholisa kumaqondo obushushu aphantsi wendawo
Ukuzijonga umboniso
* Iintlobo ezili-12 zeekhowudi ze-alam
Ukugcinwa kwesiqhelo okulula
* Ukugcinwa ngaphandle kwesixhobo sesikrini sokucoca uthuli
* Isihluzo samanzi esinokutshintshwa ngokukhawuleza esinokutshintshwa
Umsebenzi wonxibelelwano
* Ixhotyiswe nge-RS485 Modbus RTU protocol
Isifudumezi
Hluza
Iplagi esemgangathweni yase-US / iplagi ye-EN eqhelekileyo
Umlawuli wobushushu bedijithali
Isilawuli sobushushu se-T-801B sibonelela ngolawulo oluchanekileyo oluchanekileyo lobushushu obuyi-±0.1°C.
Izibuko zokuzalisa amanzi ngaphambili kunye nezibuko lokukhupha amanzi
I-port yokuzalisa amanzi kunye ne-drain port ifakwe ngaphambili ukuze kube lula ukuzaliswa kwamanzi kunye nokukhupha amanzi.
Modbus RS485 unxibelelwano port
Silapha ngenxa yakho xa usidinga.
Nceda ugcwalise ifomu ukuze uqhagamshelane nathi, kwaye siya kukuvuyela ukukunceda.
I-Ofisi ivaliwe ukusuka nge-1-5 kaMeyi, ngo-2025 ngoSuku lwaBasebenzi. Ivulwe kwakhona ngoMeyi 6. Iimpendulo zinokulibaziseka. Enkosi ngokuqonda kwakho!
Siza kuqhagamshelana kungekudala emva kokuba sibuyile.
Iimveliso ezicetyiswayo
Ilungelo lokushicilela © 2025 TEYU S&A Chiller- Onke Amalungelo Agciniwe.