loading
6u Rak Gunung RPMER-RMUP-500 kanggo UV Laser Lassfast Laser 220V
6u Rak Gunung RPMER-RMUP-500 kanggo UV Laser Lassfast Laser 220V
6u Rak Gunung RPMER-RMUP-500 kanggo UV Laser Lassfast Laser 220V
6u Rak Gunung RPMER-RMUP-500 kanggo UV Laser Lassfast Laser 220V
6u Rak Gunung RPMER-RMUP-500 kanggo UV Laser Lassfast Laser 220V
6u Rak Gunung RPMER-RMUP-500 kanggo UV Laser Lassfast Laser 220V
6u Rak Gunung RPMER-RMUP-500 kanggo UV Laser Lassfast Laser 220V
6u Rak Gunung RPMER-RMUP-500 kanggo UV Laser Lassfast Laser 220V

6U rak Gunung Chiller RMUP-500 pikeun UV laser Ultrafast laser 220V

Rak dipasang chiller RMUP-500 gaduh desain rak 6U sareng sampurna pikeun laser UV 10W-15W sareng aplikasi laser ultrafast. Ieu delivers cooling pisan tepat ±0.1°stabilitas C kalawan téhnologi kontrol PID. Mountable dina rak 6U, Sistim cooling cai industri ieu ngamungkinkeun tumpukan alat patali, nunjukkeun tingkat luhur kalenturan jeung mobilitas. Daya refrigerasi tiasa dugi ka 650W sareng catu daya anu sayogi nyaéta 220V. Pamariksaan tingkat cai dipasang di hareup kalayan indikasi anu bijaksana. Suhu cai bisa diatur antara 5°C jeung 35°C kalayan mode suhu konstan atanapi mode kontrol suhu calakan pikeun pilihan 

    Beu ...!

    Henteu aya data produk.

    angkat ka homepage
    Bubuka produk
    6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V

    Model: RMUP-500

    Ukuran Mesin: UKURAN 49 X 48 X 26 CM (P X L X T)  6U

    Garansi: 2 taun

    Standar: CE, ngahontal sareng RoHS

    Parameter produk
    Modél RMUP-500
    RMUP-500AI RMUP-500BI
    Voltaseu AC 1P 220-240V AC 1P 220-240V
    Frékuénsi 50hz 60hz
    ayeuna 0.6~5.2A 0.6~5.2A
    Max. konsumsi kakuatan 0.98kw 1kw
    Daya kompresor 0.32kw 0.35kw
    0.44HP 0.46HP
    kapasitas cooling nominal 2217Btu/h
    0.65kw
    558 Kcal/jam
    Refrigerant R-134a
    Precision ±0.1℃
    Pangurangan Kapilér
    kakuatan pompa 0.09kw
    Kapasitas tank 5.5L
    Inlet jeung outlet Rp1/2"
    Max. tekanan pompa 2.5bar
    Max. aliran pompa 15L/min
    N.W. 21kg
    G.W. 24kg
    Diménsi UKURAN 49 X 48 X 26 CM (P X L X T)  6U
    Dimensi pakét UKURAN 59 X 53 X 34 CM (P X L X T)

    Arus kerja tiasa béda dina kaayaan kerja anu béda. Inpormasi di luhur ngan ukur pikeun rujukan. Mangga tunduk kana produk dikirimkeun sabenerna.

    Fitur produk

    fungsi calakan

    * Tingkat cai tank low ngadeteksi

    * Laju aliran cai low detecting

    * Ngadeteksi suhu cai

    * Pemanasan cai coolant dina suhu ambient low


    tampilan mariksa diri

    * 12 jinis kodeu alarem

    Gampang pangropéa rutin

    * Pangropéa Toolless tina layar filter dustproof

    * Saringan cai pilihan anu tiasa diganti gancang


    Fungsi komunikasi

    * Dilengkepan protokol RS485 Modbus RTU

    Item Pilihan

                  

      Pamanas


                   

    Nyaring


                  

      colokan standar AS / colokan standar EN


    Rincian produk
    6U Rack Mount Chiller RMUP-500 Digital temperature controller

                                             Pengontrol suhu digital


    The T-801B controller hawa nawarkeun kontrol hawa precision luhur ± 0,1 ° C 

    6U Rack Mount Chiller RMUP-500 Front mounted water fill port and drain port

                                             Hareupna dipasang port eusian cai jeung port solokan


    Port eusian cai sareng palabuhan solokan dipasang di payun pikeun ngeusian cai anu gampang sareng ngocor.

    6U Rack Mount Chiller RMUP-500 Modbus RS485 communication port

                                             Modbus RS485 port komunikasi


    Port komunikasi RS485 ngamungkinkeun komunikasi sareng sistem laser.
    Sertipikat
    6U Rack Mount Chiller RMUP-500 Certificate
    Prinsip Kerja Produk

    6U Rack Mount Chiller RMUP-500 Product Working Principle

    FAQ
    Dupi S&A Chiller hiji parusahaan dagang atawa produsén?
    Kami produsén chiller industri profésional saprak 2002.
    Naon cai anu disarankeun dianggo dina chiller cai industri?
    Cai idéal kedah cai deionised, cai sulingan atawa cai dimurnikeun.
    Sabaraha lami abdi kedah ngaganti kaluar cai?
    Sacara umum, frékuénsi ganti cai nyaéta 3 bulan. Ogé bisa gumantung kana lingkungan kerja sabenerna tina chillers cai recirculating. Contona, upami lingkungan gawé teuing inferior, frékuénsi robah disarankeun jadi 1 bulan atawa pondok.
    Naon suhu kamar idéal pikeun chiller?
    Lingkungan gawé tina chiller cai industri kudu ventilated ogé sarta suhu kamar teu kudu leuwih luhur ti 45 derajat C.
    Kumaha carana nyegah chiller abdi ti katirisan?
    Pikeun pamaké nu hirup di wewengkon lintang luhur utamana dina usum tiis, aranjeunna mindeng nyanghareupan masalah cai beku. Pikeun nyegah chiller ti katirisan, aranjeunna bisa nambahkeun hiji manaskeun pilihan atawa nambahkeun anti freezer dina chiller nu. Pikeun pamakéan lengkep anti freezer, eta disarankeun pikeun ngahubungan tim rojongan customer urang (techsupport@teyu.com.cn) heula.

    Kami di dieu pikeun anjeun nalika anjeun peryogi kami.

    Mangga ngalengkepan formulir pikeun ngahubungan kami, sarta kami bakal senang pikeun mantuan anjeun.

    Produk patali
    euweuh data
    Imah         Produk           SGS & UL Chiller         Solusi cooling         Perusahaan         Sumberdaya         Kelestarian
    Hak Cipta © 2025 TEYU S&A Chiller | Peta situs     Kabijakan privasi
    Taros Kami
    email
    Palayanan Pelanggan
    Taros Kami
    email
    ngabatalkeun
    Customer service
    detect