loading
6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V
6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V
6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V
6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V
6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V
6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V
6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V
6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V

6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V

Rack mount chiller RMUP-500 features a 6U rack mount design and is perfect for 10W-15W UV laser and ultrafast laser applications. It delivers extremely precise cooling of ±0.1°C stability with PID control technology. Mountable in a 6U rack, this industrial water cooling system allows stacking of related device, indicating a high level of flexibility and mobility. The refrigerating power can reach up to 650W and the available power supply is 220V. Water level check is installed in the front with thoughtful indications. Water temperature can be set between 5°C and 35°C with constant temperature mode or intelligent temperature control mode for selection. 

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    6U Rack Mount Chiller RMUP-500 for UV Laser Ultrafast Laser 220V

    Model: RMUP-500

    Machine Size: 49X48X26cm (L X W X H)  6U

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    ModelRMUP-500
    RMUP-500AIRMUP-500BI
    VoltageAC 1P 220-240VAC 1P 220-240V
    Frequency50Hz60Hz
    Current0.6~5.2A0.6~5.2A
    Max. power consumption0.98kW1kW
    Compressor power0.32kW0.35kW
    0.44HP0.46HP
    Nominal cooling capacity2217Btu/h
    0.65kW
    558Kcal/h
    RefrigerantR-134a
    Precision±0.1℃
    ReducerCapillary
    Pump power0.09kW
    Tank capacity5.5L
    Inlet and outletRp1/2”
    Max. pump pressure2.5bar
    Max. pump flow15L/min
    N.W.21Kg
    G.W.24Kg
    Dimension49 X 48 X 26cm (L X W X H)  6U
    Package dimension59 X 53 X 34cm (L X W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    Intelligent functions

    * Low tank water level detecting

    * Low water flow rate detecting

    * Over water temperature detecting

    * Heating of the coolant water at low ambient temperature


    Self-check display

    * 12 types of alarm codes

    Easy routine maintenance

    * Toolless maintenance of dustproof filter screen

    * Quick-replaceable optional water filter


    Communication function

    * Equipped with RS485 Modbus RTU protocol

    Optional Items

                  

     Heater


                   

    Filter


                  

     US standard plug / EN standard plug


    Product Details
    6U Rack Mount Chiller RMUP-500 Digital temperature controller

                                            Digital temperature controller


    The T-801B temperature controller offers high precision temperature control of ±0.1°C. 

    6U Rack Mount Chiller RMUP-500 Front mounted water fill port and drain port

                                            Front mounted water fill port and drain port


    The water fill port and drain port are mounted in the front for easy water filling and draining.

    6U Rack Mount Chiller RMUP-500 Modbus RS485 communication port

                                            Modbus RS485 communication port


    The RS485 communication port enables communication with the laser system.
    Certificate
    6U Rack Mount Chiller RMUP-500 Certificate
    Product Working Principle

    6U Rack Mount Chiller RMUP-500 Product Working Principle

    FAQ
    Is S&A Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (techsupport@teyu.com.cn) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect