I-TEYU 6U epholile emoyeni irack chiller RMUP-500 ifaka i-6U rack mount mount kwaye ifanelekile kwi-10W-15W UV laser, i-laser ye-ultrafast, i-semiconductor kunye nezicelo zokupholisa izixhobo zebhubhoratri. Ukunyuka kwi-rack ye-6U, le nkqubo yokupholisa amanzi kwimizi-mveliso ivumela ukupakishwa kwezixhobo ezinxulumeneyo, ebonisa izinga eliphezulu lokuguquguquka kunye nokuhamba. Inika ukupholisa okuchane kakhulu kwe-±0.1°C uzinzo ngobuchwepheshe bolawulo lwe-PID.
Amandla efriji yerack intaba amanzi chiller I-RMUP-500 inokufikelela kwi-650W. Ukuhlolwa komgangatho wamanzi kufakwe ngaphambili kunye nezibonakaliso ezicingayo. Ubushushu bamanzi bunokusetwa phakathi kwe-5°C kunye ne-35°C kunye nemowudi yobushushu obungaguqukiyo okanye indlela yokulawula ubushushu obukrelekrele bokhetho.
Umzekelo: RMUP-500
Ubungakanani bomatshini: 49 X 48 X 26cm (L X W X H) 6U
Iwaranti: iminyaka emi-2
Umgangatho: CE, REACH kunye neRoHS
Umzekelo | I-RMUP-500AITY | I-RMUP-500BITY | I-RMUP-500ANPTY | I-RMUP-500BNPTY |
I-Voltage | AC 1P 220-240V | AC 1P 220-240V | AC 1P 220-240V | AC 1P 220-240V |
Ukuphindaphinda | 50Hz | 60Hz | 50Hz | 60Hz |
Okwangoku | 0.6~5.2A | 0.6~5.2A | 0.91~5.41A | 0.91~5.41A |
Max. Ukutya umbane | 0.98kW | 1kW | 1.99kW | 2.89kW |
Amandla eCompressor | 0.32kW | 0.35kW | 1.73kW | 2.09kW |
0.44HP | 0.46HP | 2.32HP | 2.8HP | |
Umthamo wokupholisa oqhelekileyo | 2217Btu/h | 4229Btu/h | ||
0.65kW | 1.24kW | |||
558Kcal/h | 1064Kcal/h | |||
Isikhenkcisi | R-134a | R-407c | ||
Ukuchaneka | ±0.1℃ | |||
Isinciphisi | I-Capillary | |||
Umthamo wetanki | 5.5L | 7L | ||
Ukungena kunye nokuphuma | Rp1/2” | |||
Impompo amandla | 0.09kW | 0.2kW | ||
Max. uxinzelelo lwempompo | 2.5 ibha | 4.0 ibha | ||
Max. ukuhamba kwempompo | 15L/min | 38L/min | ||
N.W | 21Kg | 35Kg | ||
G.W | 24Kg | 39Kg | ||
Ubungakanani | 49X48X26cm (L X W X H) 6U | 67x48x33cm (L X W X H) 7U | ||
Ubungakanani bephakheji | 59X53X34cm (L X W X H) | 74x57x50cm (L X W X H) |
Umsebenzi wangoku unokwahluka phantsi kweemeko ezahlukeneyo zokusebenza. Ezi nkcukacha zingentla zenzelwe ireferensi kuphela. Nceda uxhomekeke kweyona mveliso ithunyelweyo.
Imisebenzi ekrelekrele
Ukuzijonga umboniso
Ukugcinwa kwesiqhelo okulula
Umsebenzi wonxibelelwano
Isifudumezi
Hluza
Iplagi esemgangathweni yase-US / iplagi ye-EN eqhelekileyo
Umlawuli wobushushu bedijithali
Isilawuli sobushushu se-T-801B sinikezela ngolawulo oluchanekileyo oluchanekileyo lweqondo lokushisa ± 0.1 °C.
Izibuko zokuzalisa amanzi ngaphambili kunye nezibuko lokukhupha amanzi
I-port yokuzalisa amanzi kunye ne-drain port ifakwe ngaphambili ukuze kube lula ukuzaliswa kwamanzi kunye nokukhupha amanzi.
Modbus RS485 unxibelelwano port
Ukuba unemibuzo emininzi, sibhalele
Shiya nje i-imeyile yakho okanye inombolo yefowuni kwifom yoqhagamshelwano ukuze sikubonelele ngeenkonzo ezingakumbi!
Iimveliso ezicetyiswayo
Ilungelo lokushicilela © 2021 TEYU S&A Chiller - Onke Amalungelo Agciniwe.