TEYU I-CW-6260BNPTY-UL industrial chiller yenzelwe izixhobo zoshishino ezineemfuno eziphezulu zokupholisa, inika amandla okupholisa angama-9000W kunye nozinzo lobushushu obungama-±0.5°C ukuze kuphole inkqubo eqhubekayo. Ivavanywe ngokuzimeleyo yi-SGS ukuya kwimigangatho ye-UL kunye ne-CSA, yenzelwe ukuhlangabezana neemfuno zokhuseleko lombane zaseMntla Melika kwiindawo zoshishino ezifuna kakhulu.


Ibonisa iindlela zokulawula ubushushu ezikrelekrele, unxibelelwano lwe-RS-485 Modbus RTU, ibhokisi yokuxhuma umbane evaliweyo, ukujonga uxinzelelo lwefriji, kunye nokhuseleko olupheleleyo lwamanqanaba amaninzi, TEYU CW-6260BNPTY-UL inika ukusebenza okuthembekileyo kwiinkqubo zoshishino ezinomthwalo ophezulu. Lukhetho oluhle kakhulu kwiinkqubo ze-laser ze-CO₂ ezinamandla aphezulu, umatshini wokugaya i-CNC, ukwenziwa kwemizi-mveliso, kunye nezinye izicelo ezifuna ukupholisa okuthembekileyo ixesha elide.

Product characteristics

Product parameters

ImodeliCW-6260BNPTY-UL I-VoltageAC 1P 220~240V
Izihlandlo 60Hz Okwangoku5.4~20.5A
Ukusetyenziswa kwamandla okuphezulu 4.5kW Umthamo wokupholisa oqhelekileyo 30708Btu/h
Amandla e-compressor 3.02kW 9kW
4.11HP 7738Kcal/h
Amandla epompo 1kW Uxinzelelo olukhulu lwepompo Ibha ye-4.6
Ukuhamba okulinganisiweyo 67L/ngomzuzu IsiqandisiR-32
Uchaneko ±0.5℃ Umnciphisi I-Capillary
Umthamo wetanki40L Ukungena kunye nokuphuma I-Rp1"
N.W. 135kg Ubukhulu 87 × 65 × 118cm (Ububanzi × Ububanzi)
G.W. 153kg Ubungakanani bephakheji 95 × 77 × 135cm (Ububanzi × Ububanzi)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Ekhaya   |     Iimveliso       |     SGS & UL Chiller       |     Ukupholisa Isisombululo     |     Inkampani      |    Umthombo       |      Uzinzo
Ilungelo lokushicilela © 2026 TEYU S&A Chiller | Imephu yesiza Umgaqo-nkqubo wabucala
Qhagamshelana nathi
email
Nxibelelana nenkonzo yabathengi
Qhagamshelana nathi
email
rhoxisa
Customer service
detect