loading
Ulwimi

I-SGS-Tested Industrial Process Chiller CW-6200BNPTY-UL

I-UL kunye ne-CSA Compliant Process Chiller ye-CNC, i-Laser, kunye nezicelo zemizi-mveliso

TEYU I-CW-6200BNPTY-UL industrial chiller yenzelwe ukusetyenziswa kweenkqubo zokupholisa zemizi-mveliso ezifuna ulawulo lobushushu oluthembekileyo kunye nozinzo lokusebenza ixesha elide. Inika amandla okupholisa angama-5100W kunye nozinzo lobushushu obuzinzo lwe-±0.5°C, ivavanywa ngokuzimeleyo yi-SGS ukuya kwimigangatho ye-UL kunye ne-CSA kwaye yakhelwe ukuxhasa ukusetyenziswa kwemizi-mveliso yaseMntla Melika.


Ixhotyiswe ngeendlela zokulawula ubushushu ezikrelekrele, unxibelelwano lwe-RS-485 Modbus RTU, ibhokisi yokuxhuma umbane evaliweyo, kunye nokhuseleko olunamanqanaba amaninzi, TEYU CW-6200BNPTY-UL idibana ngokulula nezixhobo ezahlukeneyo zoshishino. Ifanelekile kwizixhobo zoomatshini be-CNC, iinkqubo ze-laser ze-CO₂, izixhobo zokuprinta, oomatshini bokupakisha, kunye nezinye izicelo zokuphola eziqhubekayo.

Product characteristics

Product parameters

ImodeliCW-6200BNPTY-UL I-VoltageAC 1P 220~240V
Izihlandlo 60Hz Okwangoku3.4~10.4A
Ukusetyenziswa kwamandla okuphezulu 2.3kW Umthamo wokupholisa oqhelekileyo 17401Btu/h
Amandla e-compressor 1.39kW 5.1kW
1.89HP 4384Kcal/h
Amandla epompo 0.75kW Uxinzelelo olukhulu lwepompo Ibha ezi-5
Ukuhamba okulinganisiweyo 33L/ngomzuzu IsiqandisiR-32
Uchaneko ±0.5℃ Umnciphisi I-Capillary
Umthamo wetanki22L Ukungena kunye nokuphuma Rp1/2"
N.W. 76kg Ubukhulu 67 × 47 × 90cm (L × W × H)
G.W. 87kg Ubungakanani bephakheji 73 × 57 × 105cm(Ububanzi × Ububanzi)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Ekhaya   |     Iimveliso       |     SGS & UL Chiller       |     Ukupholisa Isisombululo     |     Inkampani      |    Umthombo       |      Uzinzo
Ilungelo lokushicilela © 2026 TEYU S&A Chiller | Imephu yesiza Umgaqo-nkqubo wabucala
Qhagamshelana nathi
email
Nxibelelana nenkonzo yabathengi
Qhagamshelana nathi
email
rhoxisa