I-heater
Hlunga
Ipulaki elijwayelekile lase-US / ipulaki elijwayelekile le-EN
Ingabe ufuna i-compact, i-chiller yamanzi enembile yelaser yakho ye-UV engu-3-5W? I-TEYU CWUP-05THS laser chiller idizayinelwe ukuthi ilingane nezikhala eziqinile (39×27×23 cm) kuyilapho iletha ukuqina kwezinga lokushisa elingu-±0.1°C. Isekela amandla angu-220V 50/60Hz futhi ilungele ukumaka nge-laser, ukuqoshwa, nezinye izinhlelo zokusebenza ze-laser ye-UV ezidinga ukupholisa okunembayo.
Nakuba incane ngosayizi, i-TEYU laser chiller CWUP-05THS ifaka ithangi lamanzi elikhulu umthamo wokusebenza okuzinzile, ama-alamu agelezayo namaleveli okuphepha, kanye nesixhumi sezindiza esingu-3-core ukuze sisebenze okuthembekile. Ukuxhumana kwe-RS-485 kuvumela ukuhlanganiswa kwesistimu okulula. Ngamazinga omsindo angaphansi kuka-60dB, yisixazululo esithulile, esisebenza kahle sokupholisa esithenjwa kumasistimu e-laser we-UV.
Imodeli: CWUP-05THS
Usayizi Womshini: 39X27X23cm (LXWXH)
Iwaranti: iminyaka emi-2
Okujwayelekile: CE, REACH kanye ne-RoHS
Imodeli | I-CWUP-05THSTY |
Amandla kagesi | I-AC 1P 220-240V |
Imvamisa | 50/60Hz |
Okwamanje | 0.5~5.9A |
Ubukhulu. ukusetshenziswa kwamandla | 1.2/1.3kW |
| 0.18/0.21kW |
0.24/0.28HP | |
Amandla okupholisa okuzisholo | 1296/1569Btu/h |
0.38kW | |
326/395Kcal/h | |
Isiqandisi | R-134a |
Ukunemba | ±0.1℃ |
Umnciphisi | I-Capillary |
Amandla wepompo | 0.05kW |
Umthamo wethangi | 2.2L |
I-Inlet ne-outlet | Rp1/2” |
Ubukhulu. umfutho wephampu | 1.2 ibha |
Ubukhulu. ukugeleza kwepompo | 13L/min |
NW | 14Kg |
GW | 16Kg |
Ubukhulu | 39X27X23cm (LXWXH) |
Ubukhulu bephakheji | 44X33X29cm (LXWXH) |
Amandla okusebenza angahluka ngaphansi kwezimo zokusebenza ezihlukene. Imininingwane engenhla ingeyereferensi kuphela. Sicela uncike kumkhiqizo wangempela olethiwe.
Imisebenzi ehlakaniphile
* Ukuthola izinga lamanzi ethangi eliphansi
* Ukuthola izinga lokugeleza kwamanzi aphansi
* Ukuthola izinga lokushisa elingaphezu kwamanzi
* Ukushisa kwamanzi apholile ezingeni eliphansi lokushisa elizungezile
Isibonisi sokuzihlola
* Izinhlobo eziyi-12 zamakhodi e-alamu
Ukugcinwa okulula kwesimiso
* Ukugcinwa okungenamathuluzi kwesikrini sokuhlunga esingangeni uthuli
* Isihlungi samanzi ongasikhetha esishintshwa ngokushesha
Umsebenzi wokuxhumana
* Ifakwe RS485 Modbus RTU protocol
I-heater
Hlunga
Ipulaki elijwayelekile lase-US / ipulaki elijwayelekile le-EN
Isilawuli sokushisa kwedijithali
Isilawuli sezinga lokushisa i-T-801C sinikeza ukulawula okunemba okuphezulu kwezinga lokushisa okungu-±0.1°C.
Inkomba yezinga lamanzi efundeka kalula
Inkomba yezinga lamanzi inezindawo ezinemibala emi-3 - ophuzi, oluhlaza okotshani nobomvu.
Indawo ephuzi - izinga eliphezulu lamanzi.
Indawo eluhlaza - izinga lamanzi elivamile.
Indawo ebomvu - izinga eliphansi lamanzi.
Ichweba lokuxhumana le-Modbus RS-485
Sikhona ngenxa yakho uma usidinga.
Sicela ugcwalise ifomu ukuze uxhumane nathi, futhi sizokujabulela ukukusiza. .
Ihhovisi livalwe kusukela ngoMeyi 1–5, 2025 ngoSuku Lwabasebenzi. Kuvulwe kabusha ngoMeyi 6. Izimpendulo zingase zibambezeleke. Siyabonga ngokuqonda kwakho!
Sizoxhumana maduze ngemuva kokubuya.
Imikhiqizo Enconyiwe