loading
Ulimi

I-SGS-Tested Industrial Process Chiller CW-6260BNPTY-UL

I-UL & CSA Compliant High-Capacity Process Chiller yezinhlelo zokupholisa zezimboni

TEYU I-CW-6260BNPTY-UL industrial chiller yenzelwe imishini yezimboni enezidingo eziphezulu zokupholisa, inikeza amandla okupholisa angu-9000W kanye nokuqina kokushisa okungu-±0.5°C ukuze kuphole inqubo eqhubekayo. Ihlolwe ngokuzimela yi-SGS kuya kumazinga e-UL kanye ne-CSA, yenzelwe ukuhlangabezana nezidingo zokuphepha kukagesi zaseNyakatho Melika ezindaweni zezimboni ezidinga kakhulu.


Iqukethe izindlela zokulawula izinga lokushisa ezihlakaniphile, ukuxhumana kwe-RS-485 Modbus RTU, ibhokisi lokuxhumanisa ugesi elivaliwe, ukuqapha ingcindezi yesiqandisi, kanye nokuvikelwa okubanzi kwamazinga amaningi, TEYU CW-6260BNPTY-UL inikeza ukusebenza okuthembekile kwezinqubo zezimboni ezithwala umthwalo omkhulu. Kuyisinqumo esihle kakhulu sezinhlelo ze-laser ze-CO₂ ezinamandla aphezulu, imishini ye-CNC, ukukhiqizwa kwezimboni, kanye nezinye izinhlelo zokusebenza ezidinga ukupholisa okuthembekile kwesikhathi eside.

Product characteristics

Product parameters

ImodeliCW-6260BNPTY-UL I-voltageAC 1P 220~240V
Imvamisa 60Hz Okwamanje5.4~20.5A
Ukusetshenziswa kwamandla okuphezulu 4.5kW Umthamo wokupholisa ojwayelekile 30708Btu/h
Amandla e-compressor 3.02kW 9kW
4.11HP 7738Kcal/h
Amandla ephampu 1kW Umfutho ophezulu wephampu Ibha engu-4.6
Ukugeleza okulinganiselwe 67L/umzuzu IsiqandisiR-32
Ukunemba ±0.5℃ Isinciphisi I-Capillary
Umthamo wethangi40L Ukungena kanye nokukhipha I-Rp1"
N.W. 135kg Ubukhulu 87 × 65 × 118cm (Ububanzi × Ububanzi)
G.W. 153kg Ubukhulu bephakheji 95 × 77 × 135cm (Ububanzi × Ububanzi)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Ikhaya   |     Imikhiqizo       |     I-SGS & UL Chiller       |     Isixazululo Sokupholisa     |     Inkampani      |    Insiza       |      Ukusimama
Ilungelo Lokushicilela © 2026 TEYU S&A Chiller | Imephu Yesayithi Inqubomgomo Yobumfihlo
Xhumana nathi
email
Xhumana nenkonzo yamakhasimende
Xhumana nathi
email
hlikihla
Customer service
detect