loading

UL-Certified Chiller CWFL-15000KN

Ideal for Cooling 12kW | 15kW Fiber Laser

The 12kW-15kW fiber laser is widely used in precision applications such as cutting, welding, and surface treatment, and requires a reliable cooling solution to maintain stable performance and ensure safety. TEYU industrial chiller CWFL-15000KNTY is specifically designed for 12kW-15kW fiber lasers, offering superior cooling and reliability in demanding industrial environments. It helps maintain optimal temperatures, preventing overheating and damage to the laser and its components.


Equipped with a dual-cooling loop system, industrial chiller CWFL-15000KNTY independently cools both the fiber laser and optics, ensuring consistent performance under heavy loads. It features an intelligent temperature controller that optimizes energy use, while bypass valve technology reduces compressor wear and extends lifespan. With built-in alarms for protection and RS-485 control for easy monitoring, this chiller is the ideal cooling solution for 12kW-15kW fiber laser equipment, ensuring long-term reliability and efficiency.

no data

Product characteristics

no data

Product parameters

Model

 CWFL-15000KNTY (UL)

Voltage

AC 3P 460V

Frequency

60Hz

Current

10.6~42.6A

Max. power consumption

23.8kW

Heater power

1000W+4800W

Precision

±1℃

Reducer

Thermostatic expansion valve

Pump power

5.5kW

Tank capacity

210L

Inlet and outlet

Rp1/2"+ Rp1-1/2"

Max. pump pressure

5.8bar

Rated flow

5L/min+>150Lmin

Dimension

190 X 108 X 140cm (L X W X H)

N.W.

538Kg

Package dimension

203 X 123 X 162cm (L X W X H)

G.W.

613Kg

  

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.
no data

Details

Multiple warning protections Water level alarm, over-temperature alarm, water flow alarm, etc.
Thermal insulation for water tubing, pump and evaporator.
Support ModBus 485 communication: real-time monitoring and remote control
no data
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Stainless steel filter
Recyclable and anti-clogging
Water pressure gauge
Display of water pump status and water pressure
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Dual compressor
Fully hermetic compressors with built-in motor protection, smart startup.
no data

Certificate

Working principle

Product Working Principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
Contact us
email
Contact customer service
Contact us
email
cancel
Customer service
detect