loading
Lus

SGS-Tested fiber ntau Laser Chiller CWFL-12000KNPTY-UL

UL & CSA Ua Raws Li Kev Lag Luam Chiller rau 12kW Fiber Laser Systems

TEYU CWFL-12000KNPTY-UL lub tshuab cua txias rau kev lag luam yog tsim los rau 12kW fiber laser systems, muab 35kW lub peev xwm txias nrog ob lub voj voog txias ywj pheej rau kev tswj hwm thermal meej. Tau kuaj ywj pheej los ntawm SGS rau UL & CSA cov qauv, nws txhawb nqa North American cov kev cai hluav taws xob thiab xa cov cua txias txhim khu kev qha rau cov ntawv thov laser kev lag luam muaj zog siab.


Nruab nrog kev tswj qhov kub thiab txias ob chav ntse, kev sib txuas lus RS-485 Modbus RTU, thiab kev tiv thaiv ntau theem, TEYU CWFL-12000KNPTY-UL zoo rau cov kab ntau lawm tsis siv neeg thiab cov chaw tsim khoom ntse. Nws pab txhim kho kev ntseeg siab ntawm cov khoom siv, txo lub sijhawm tsis ua haujlwm, thiab txhawb kev ua haujlwm tas mus li mus sij hawm ntev.

Product characteristics

Product Parameters

QauvCWFL-12000KNPTY-UL Hluav taws xobAC 3P 460V~480V
Zaus 60Hz Tam sim no3.7~28.4 A
Kev siv hluav taws xob siab tshaj plaws 19.3kW Lub zog cua sov600W+3600W
Lub peev xwm txias nominal 119424Btu/teev Cov tshuaj txiasR-32
35kW Kev Ntsuas Tseeb ±1℃
30094Kcal/teev Txo qhov Cov hlab ntsha capillary
Lub zog twj tso kua mis 3kW Lub peev xwm ntawm lub tank170L
Qhov nkag thiab qhov hluav taws xob Rp1/2"+Rp1-1/4" Siab tshaj plaws ntawm lub twj tso kua mis 6 bar
Ntsuas ntws 2.5L/feeb+>133L/feeb Qhov Loj 145 × 80 × 132cm (Ntev × Dav × Siab)
N.W. 290kg Qhov ntev ntawm pob khoom 147 × 92 × 150cm (Ntev × Dav × Siab)
G.W. 333kg

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop available to instantly eliminate hazards
Emergency Stop available to instantly eliminate hazards
Multiple warning protections: water level alarm, over-temperature alarm, water flow alarm...
Thermal insulation for water tubing, pump and evaporator.
Fully hermetic compressor with built-in motor protection.
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Stainless steel filter
Recyclable and anti-clogging
Water pressure gauge
Display of water pump status and water pressure
Waterproof junction box
Safe and stable, flexible power cable installation
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Tsev   |     Cov khoom       |     SGS thiab UL Chiller       |     Txias Solution     |     Tuam txhab      |    Cov peev txheej       |      Sustainability
Luam tawm © 2026 TEYU S&A Chiller | Txoj cai tswjfwm ntiag tug
Tiv tauj peb
email
Hu rau cov neeg siv khoom pabcuam
Tiv tauj peb
email
tshem
Customer service
detect