SGS-Kuaj Xyuas Kev Lag Luam Txheej Txheem Chiller CW-6200BNPTY-UL

UL & CSA Ua Raws Li Cov Txheej Txheem Chiller rau CNC, Laser, thiab Kev Siv Hauv Kev Lag Luam

TEYU CW-6200BNPTY-UL lub tshuab cua txias rau kev lag luam yog tsim los rau cov txheej txheem txias hauv kev lag luam uas xav tau kev tswj qhov kub thiab txias thiab kev ua haujlwm ruaj khov mus sij hawm ntev. Muab 5100W lub peev xwm txias nrog ± 0.5 ° C qhov kub thiab txias ruaj khov, nws tau kuaj xyuas los ntawm SGS rau UL & CSA cov qauv thiab tsim los txhawb cov ntawv thov kev lag luam hauv North American.


Nruab nrog cov hom kev tswj kub ntse, RS-485 Modbus RTU kev sib txuas lus, lub thawv hluav taws xob kaw, thiab kev tiv thaiv ntau theem, TEYU CW-6200BNPTY-UL sib koom ua ke yooj yim nrog ntau yam khoom siv hauv kev lag luam. Nws zoo heev rau cov cuab yeej tshuab CNC, CO₂ laser systems, cov khoom siv luam ntawv, cov tshuab ntim khoom, thiab lwm yam kev siv txias tas mus li.

Product characteristics

Product parameters

QauvCW-6200BNPTY-UL Hluav taws xobAC 1P 220~240V
Zaus 60Hz Tam sim no3.4~10.4A
Kev siv hluav taws xob siab tshaj plaws 2.3kW Lub peev xwm txias nominal 17401Btu/teev
Lub zog compressor 1.39kW 5.1kW
1.89HP 4384Kcal/teev
Lub zog twj tso kua mis 0.75kW Siab tshaj plaws ntawm lub twj tso kua mis 5 bar
Ntsuas ntws 33L/feeb Cov tshuaj txiasR-32
Kev Ntsuas Tseeb ±0.5℃ Txo qhov Cov hlab ntsha capillary
Lub peev xwm ntawm lub tank22L Qhov nkag thiab qhov hluav taws xob Rp1/2"
N.W. 76kg Qhov Loj 67 × 47 × 90cm (L × W × H)
G.W. 87kg Qhov ntev ntawm pob khoom 73 × 57 × 105cm (Ntev × Dav × Siab)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Tsev   |     Cov khoom       |     SGS thiab UL Chiller       |     Txias Solution     |     Tuam txhab      |    Cov peev txheej       |      Sustainability
Luam tawm © 2026 TEYU S&A Chiller | Txoj cai tswjfwm ntiag tug
Tiv tauj peb
email
Hu rau cov neeg siv khoom pabcuam
Tiv tauj peb
email
tshem
Customer service
detect