loading
Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability Modbus-485 Communication 1
Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability Modbus-485 Communication 2
Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability Modbus-485 Communication 3
Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability Modbus-485 Communication 4
Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability Modbus-485 Communication 1
Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability Modbus-485 Communication 2
Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability Modbus-485 Communication 3
Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability Modbus-485 Communication 4

Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability Modbus-485 Communication

Our expertise in high precision cooling technology translates into this small laser process water chiller CWUP-40. This chiller may be simple in design yet it delivers precise cooling featuring ±0.1°C stability with PID control technology and steady flow of chilled water for your ultrafast lasers and UV lasers. Modbus 485 communication function is designed to provide effective communication between chiller and laser system. 

TEYU ultrafast precision laser chiller CWUP-40 is completely self-contained, it combines a high efficiency compressor and a durable fan-cooled condenser and is suitable for purified water, distilled water or deionised water. The water fill port and drain port are mounted on the back together with a thoughtful water level check. Intelligent digital control panel displays the temperature and built-in alarm codes. This chiller is environmentally friendly, energy-saving, high-efficiency, and certified by CE, RoHS and REACH.

    Me paenitet ...!

    productum sine notitia.

    ad homepage
    Introductio Producti
    Ultrafast Precision Laser Process Cooling System CWUP-40 ±0.1°C Stability

    Modellum: CWUP-40

    Magnitudo Machinae: 67X47X89cm (LXWXH)

    Garantia: biennium

    Norma: CE, REACH et RoHS

    Parametri Producti
    Modellum CWUP-40ANTY CWUP-40BNTY CWUP-40AN5TY CWUP-40BN5TY
    Tensio electrica AC 1P 220-240V AC 1P 220-240V AC 1P 220~240V AC 1P 220~240V
    Frequentia 50Hz 60Hz 50Hz 60Hz
    Currens 2.3~11.3A 2.1~12A 3.4~21.4A 3.9~21.1A

    Maximus consumptio energiae

    2.14kilowatt 2.36kilowatt 3.83kilowatt 4.03kilowatt


    Potentia compressoris

    0.88kilowatt 1.08kilowatt 1.75kilowatt 1.7kilowatt
    1.18HP 1.44HP 2.34HP 2.27HP


    Capacitas refrigerandi nominalis

    10713Btu/h 17401Btu/h
    3.14kilowatt 5.1kilowatt
    2699Kcal/h 4384Kcal/h
    Refrigerans R-410A
    Praecisio ±0.1℃
    Reductor Capillaris
    Vis antliae 0.37kilowatt 0.55kilowatt 0.75kilowatt
    Capacitas cisternae 14L
    Introitus et exitus Rp1/2”

    Maximus pressio antliae

    2.7vectis 4.4vectis 5.3vectis
    Maximus fluxus antliae 75L/min
    N.W. 58chiliogrammata 67chiliogrammata
    G.W. 70chiliogrammata 79chiliogrammata
    Dimensio 67X47X89cm (LXA XA)
    Dimensio sarcinae 73X57X105cm (LXA XA)

    Currens operans sub variis condicionibus operandi variari potest. Informationes supradictae ad referentiam tantum sunt. Quaeso, secundum rem ipsam traditam, spectare debes.

    Proprietates Producti

    Functiones intelligentes

    * Detectio aquae humilis in cisterna

    * Detectio fluxus aquae humilis

    * Temperatura aquae supra detegendum

    * Calefactio aquae refrigerantis ad temperaturam ambientis humilem

    Ostentatio auto-probationis

    * Duodecim genera codicum alarmis

    Facilis cura ordinaria

    * Cura sine instrumentis cribri filtratorii pulveris resistentis

    * Filtrum aquae celeriter substituibile, quod optio praebetur

    Functio communicationis

    * Protocollo RS485 Modbus RTU instructum

    Res Optionales

                  

      Calefactor

     

                   

    Filtrum

     

                  

      Obturaculum normae Americanae / obturaculum normae EN

     

    Singula Producti
    Ultrafast Precision Laser Process Cooling System CWUP-40 Digital temperature controller

                                             Regulator temperaturae digitalis

     

    Regulator temperaturae T-801B praecisionem magnam moderationis temperaturae praebet. ±0.1°C 

    Ultrafast Precision Laser Process Cooling System CWUP-40 Easy-to-read water level indicator

                                             Indicator aquae facile legendus

     

    Indicator livelli aquae tres areas colorum habet - flavum, viridem et rubrum.

    Regio flava - altus aquae altitudo.

    Area viridis - aquae altitudo normalis.

    Area rubra - aquae altitudo humilis.

    Modbus RS485 communication port integrated in the electrical connecting box

                                             Portus communicationis Modbus RS485 in arca connexionum electricarum integratus 

     

    Portus communicationis RS485 in arca conexuum electricorum integratus communicationem cum systemate laserico permittit.
    Distantia Ventilationis

    Ultrafast Precision Laser Process Cooling System CWUP-40 Ventilation Distance

    Certificatum
    Ultrafast Precision Laser Process Cooling System CWUP-40 Certificate
    Principium Operationis Producti

    Ultrafast Precision Laser Process Cooling System CWUP-40 Product Working Principle

    FAQ
    Estne TEYU Chiller societas mercatoria an fabricator?
    Fabricatores professionales refrigeratorum industrialium ab anno MMII sumus.
    Quaenam aqua in refrigeratore aquae industriali adhibenda commendatur?
    Aqua optima debet esse aqua deionizata, aqua destillata, vel aqua purificata.
    Quam saepe aquam mutare debeo?
    Generaliter loquendo, frequentia mutationis aquae est tres menses. Etiam pendere potest ex vero ambitu laboris refrigeratorum aquae recirculantis. Exempli gratia, si ambitus laboris nimis inferior est, frequentia mutationis uno mense vel brevior esse suggeritur.
    Quae est temperatura cubiculi optima pro refrigeratore industriali?
    Locus ubi refrigerator aquae industrialis laborat bene ventilatus esse debet, et temperatura cubiculi non plus quam 45 gradus Celsius excedat.
    Quomodo refrigeratorium meum ne congelescat prohibeam?
    Usuarii in regionibus altae latitudinis, praesertim hieme, habitantes saepe problema aquae congelatae patiuntur. Ne frigidarium congelescat, calefactorem optionalem vel medicamentum anticongelans in frigidario addere possunt. Ad usum accuratum anticongelantis, suadetur ut turmam auxilii clientium nostram contactes. (service@teyuchiller.com) primum.

    Adsumus tibi cum nobis opus est.

    Quaeso, formam imple ut nobiscum communicare possis, et libenter te adiuvabimus.

    Producta Similia
    absque notitia
    Ius proprietatis © MMXV TEYU S&Refrigerator | Index situs     Consilium de secreto
    Nobis loquere
    email
    Contact Customer Service
    Nobis loquere
    email
    inrita
    Customer service
    detect