Water chiller news
Why the high temperature alarm of the fiber laser happens so often in summer ? 2018-11-23

Client: Hello. My fiber laser is now having the high temperature alarm, but the equipped S&A CWFL-1500 water chiller is not. Why?

S&A: Let me explain to you. S&A CWFL-1500 water chiller has two independent temperature control systems (i.e. high temperature system for cooling QBH connector (lens) while the low temperature system for cooling the laser body). For the high temperature control system of the chiller (for lens cooling), the default setting is intelligent mode with 45℃default alarm value of ultrahigh water temperature, but the alarm value for the lens of your fiber laser is 30℃, which may possibly result in the situation that the fiber laser has the alarm but the water chiller has not. In this case, in order to avoid the high temperature alarm of the fiber laser, you can reset the water temperature of the high temperature control system of the chiller.

Below are two methods of water temperature setting of the high temperature control system for S&A chiller.(Let’s take T-506(high temp. system) as an example).

Method One: Adjust the T-506 (High Temp.) from intelligent mode to constant temperature mode and then set the required temperature.

Steps:
1.Press and hold “▲”button and “SET” button for 5 seconds
2.until the upper window indicates “00” and the lower window indicates “PAS”
3.Press “▲” button to select the password “08” (default setting is 08)
4.Then press “SET” button to enter menu setting
5.Press “▶” button until the lower window indicates “F3”. (F3 stands for way of control)
6.Press “▼” button to modify the data from “1” to “0”. (“1” means intelligent mode while “0” means constant temperature mode)
7.Press “SET” button and then press “◀” button to select “F0”(F0 stands for temperature setting)
8.Press “▲” button or “▼” button to set the required temperature
9.Press “RST” to save the modification and exit the setting.


Method Two: Lower the allowed highest water temperature under intelligent mode of T-506 (High Temp.)

Steps:
1.Press and hold “▲” button and “SET” button for 5 seconds
2.until the upper window indicates “00” and the lower window indicates “PAS”
3.Press “▲” button to select the password (default setting is 08)
4.Press “SET” button to enter menu setting
5. Press “▶” button until the lower window indicates “F8” (F8 means the allowed highest water temperature)
6. Press “▼” button to modify the temperature from 35℃ to 30℃ (or required temperature)
7. Press “RST” button to save the modification and exit the setting.
fiber laser chiller
Why us
  • Technology Leader Technology Leader
    Provide systematic products and customized service Products diversification and wide applications More than 90 chiller models to choose More than 120 chiller models available for customization Applicable to over 100 manufacturing and processing industries Cooling capacity ranging from 0.6kW to 30 kW Technology Advantage a. With 16 years development, gradually grow as the industry standard builder and quality guarantee. b. ±0.1℃ high precision temperature control, stable cooling performance, support ModBus-485 communication, which can realize the commnucation between the laser system and multiple water chillers to achieve two functions: monitoring the working status of the chillers and modifying the parameters of the chillers, constant temperature and intelligent temperature control modes. c. With excellent laboratory testing system, simulates actual working environment for chiller. Overall performance testing before delivery: aging test and complete performance test must be executed on each finished chiller. Product Advantage a. With 11 patent certificates and won Quality integrity Level A certificate; b. ISO 9001, CE, RoHS and REACH environmental certificated. c. Conforms to air transport requirements, energy saving and environment friendly. d. Offer customized service to fulfill various demands of customer. e. Independent production of sheet metal, evaporator and condenser,minmize risks of water and refrigerant leakage and improve quality.
  • Production Advantage Production Advantage
    18,000 square meters brand new industrial refrigeration system research center and production base. Strictly execute ISO production management system, using mass modularized standard produces, and standard parts rate up to 80% which are the source of quality stability. Annual production capacity of 60,000 units, focus on large, medium and small power chiller production and manufacture. S&A Chiller Quality Control System Purchasing Strictly control and manage supply chain Ensure that each component is compliant with using standard Pre-production control Full inspection on key components Aging test on key components Production assembly process Standardized implementation on technology Assemble the chillers in strict accordance with specific regulated manufacturing procedures. Before delivery Overall performance testing Aging test and complete performance test must be executed  on each finished chiller. Delivery Delivery on time Shorten the overall response cycle of customer's supply chain Customer service 2 years warranty Lifetime maintaince and repair 24/7 hotline service with quick response
  • S&A chiller sales network S&A chiller sales network
    THE WARRANTY IS 2 YEARS AND THE PRODUCT IS UNDERWRITTEN BY INSURANCE COMPANY.  S&A has established service points in Russia, Australia, Czech, Singapore, Korea and Taiwan.

Copyright © 2018 GUANGZHOU TEYU ELECTROMECHANICAL CO.,LTD. All Rights Reserved. Powered by dyyseo.com

| Sitemap | XML
welcome to S&A
If you have any problem when using the website or our products, please write down your comments or suggestions, we will answer your questions as soon as possible!Thank you for your attention!

Home

Products

中文版

contact