loading
Ulwimi

I-SGS-Tested Fiber Laser Chiller CWFL-3000BNPTY-UL

I-UL kunye ne-CSA Compliant Industrial Chiller ye-3-4kW Fiber Lasers

TEYU I-CWFL-3000BNPTY-UL industrial chiller yenzelwe iinkqubo zokusika kunye nokuwelda ze-fiber laser ze-3–4kW, ibonelela ngeesekethe zokupholisa ezizimeleyo ezimbini ukuze zipholise ngokwahlukeneyo umthombo we-laser kunye ne-optics. Ivavanywe ngokuzimeleyo yi-SGS ukuya kwimigangatho ye-UL kunye ne-CSA, yenzelwe ukuhlangabezana neemfuno zokhuseleko lombane eMntla Melika ngelixa ixhasa ukusebenza okuthembekileyo kwiindawo zoshishino ezifuna amandla.


Iquka ulawulo lobushushu oluphindwe kabini olukrelekrele, unxibelelwano lwe-RS-485 Modbus RTU, uyilo oluchasene nokufuma kunye nokhuseleko olunamanqanaba amaninzi, TEYU CWFL-3000BNPTY-UL idibana ngokulula neenkqubo ze-laser zanamhlanje ngelixa inceda ukugcina ukusebenza okuzinzileyo kokucubungula. Uyilo lwayo oluncinci kunye nokupholisa okuthembekileyo kuyenza ibe sisisombululo esifanelekileyo kubavelisi bezixhobo ze-laser ze-OEM, abahlanganisi beenkqubo, kunye nezicelo zokwenza isinyithi kwimizi-mveliso.

Ivavanyiwe yi-SGS

Imigangatho ye-UL kunye ne-CSA iqinisekisiwe

UL 508A

Inkqubo yoLawulo eQinisekisiweyo

Ivunyiwe yi-CSA

Izixhobo zoKhuseleko eziQinisekisiweyo

I-US kunye ne-CA zilungile

Iyahambelana ne-230V/60Hz/1Ph

Iimbonakalo

Utshintsho Lokumisa Olungxamisekileyo
Ukuvalwa kwangoko ukuze kuphuculwe ukhuseleko lomqhubi kunye nezixhobo.
Ukupholisa iisekethe ezimbini
Iisekethe ezizimeleyo zibonelela ngokupholisa okwahlukileyo komthombo welaser kunye ne-optics.
±0.5°C Uzinzo lobushushu
Igcina ukupholisa okuzinzileyo ukuze isebenze ngokuthembekileyo.
I-RS-485 Modbus RTU
Ixhasa ukuhlanganiswa neenkqubo zokwenza izinto ngokuzenzekelayo, ukubeka esweni, kunye neenkqubo ze-MES.
Ukhuseleko lwe-Alarm olunamanqanaba amaninzi
Ifumanisa iimeko ezingaqhelekanga ukunceda ukunciphisa ixesha lokungasebenzi elingalindelekanga.
Uyilo oluchasene nokufutha kwamanzi
Isifudumezi esakhelwe ngaphakathi kunye nesitshintshi sobushushu zinceda ekuthinteleni ukufuma kwe-optical.

Iiparamitha zemveliso

ImodeliCWFL-3000BNPTY-UL I-VoltageAC 1P 220V
Izihlandlo 60Hz Okwangoku4.5-26.7A
Ukusetyenziswa kwamandla okuphezulu 6.4kW Amandla eheater800W+1800W
Umthamo wokupholisa oqhelekileyo 31050Btu/h IsiqandisiR-32
9.1kW Uchaneko ±0.5℃
7824Kcal/h Ukuhamba okulinganisiweyo I-Capillary
Amandla epompo 1kW Umthamo wetanki40L
Ukungena kunye nokuphuma Rp1 /2” + Rp1” Uxinzelelo olukhulu lwepompo Ibha ye-4.6
Ukuhamba okulinganisiweyo 2L/umzuzu+ >67L/umzuzu Ubukhulu 87 × 65 × 117cm (Ububanzi × Ububanzi)
N.W. 135kg Ubungakanani bephakheji 95 × 77 × 135cm (Ububanzi × Ububanzi)
G.W. 150kg

Iinkcukacha

Isilawuli sobushushu se-North American chiller CWFL-3000BNP
Bonisa ubushushu bamanzi belaser & optics ukupholisa iisekethe Uzinzo lobushushu ±0.5℃
Uqhagamshelo lwamanzi lwe-North American chiller CWFL-3000BNP
Yenzelwe ukuba kube lula ukuyifaka nokulungisa
Ibhokisi yokudibanisa ye-North American chiller CWFL-3000BNP
Ikhuselekile kwaye izinzile, ufakelo lwentambo yamandla ethambileyo
Umlandeli we-Axial we-North American chiller CWFL-3000BNP
Ukuzola, ukutshabalalisa ubushushu okusebenzayo kunye nokugcinwa simahla
Isixhobo sokulinganisa uxinzelelo lwamanzi se-North American chiller CWFL-3000BNP
Umboniso wesimo sempompo yamanzi kunye noxinzelelo lwamanzi
Isifudumezi seMntla American chiller CWFL-3000BNP
Ukwandisa ubushushu bamanzi kwaye uthintele ukujiya

Isatifikethi

Isatifikethi seFiber Laser Chiller se-3kW - iChiller yaseMntla Melika CWFL-3000BNP

Umgaqo wokusebenza

Umgaqo wokusebenza we-chiller ye-laser yefayibha ye-3kW - i-chiller yaseMntla Melika i-CWFL-3000BNP

Umgama wokungenisa umoya

Umgama wokungenisa umoya-kuMntla waseMelika chiller CWFL-3000BNP

FAQ

1
Ngaba i-TEYU Chiller yinkampani yokurhweba okanye umenzi?
Singabantu abaqeqeshiweyo abavelisa i-chiller ukususela ngo-2002.
2
Ngawaphi amanzi acetyiswayo asetyenziswa kwindawo yokupholisa amanzi kwimizi-mveliso?
Amanzi afanelekileyo kufuneka abe ngamanzi adibeneyo, amanzi adibeneyo okanye amanzi ahlambulukileyo.
3
Kufuneka nditshintshe kangaphi amanzi?
Ngokuqhelekileyo, amaxesha okutshintsha amanzi ziinyanga ezi-3. Isenokuxhomekeka kwakhona kwindawo ekusetyenzwa kuyo yokwenyani yeendawo zokupholisa amanzi ezijikelezayo. Ngokomzekelo, ukuba indawo yokusebenza iphantsi kakhulu, i-frequency eguqukayo icetyiswa ukuba ibe yinyanga eyi-1 okanye imfutshane.
4
Leliphi elona qondo lobushushu kwigumbi lendawo yokupholisa amanzi?
Indawo yokusebenza yendawo yokupholisa amanzi kwimizi-mveliso kufuneka ingene umoya kakuhle kwaye ubushushu begumbi akufunekanga bube ngaphezu kwama-45 degrees C.
5
Uyithintela njani i-chiller yam ekubeni yingqele?
Kubasebenzisi abahlala kwiindawo eziphezulu zobude ingakumbi ebusika, bahlala bejongana nengxaki yamanzi angumkhenkce. Ukuthintela i-chiller ekukhenkceni, bangongeza isifudumezi esikhethiweyo okanye bongeze i-anti-freezer kwi-chiller. Usetyenziso oluneenkcukacha lwe-anti-freezer, kucetyiswa ukuba uqhagamshelane neqela lethu lenkxaso yabathengi (service@teyuchiller.com ) Ekuqaleni.

Silapha ngenxa yakho xa usidinga.

Nceda ugcwalise ifomu ukuze uqhagamshelane nathi, kwaye siya kukuvuyela ukukunceda.

Umenzi weChiller | TEYU iiChiller zokupholisa i-CO2, ifayibha, i-CNC, kunye nokusetyenziswa kwenkqubo.
Ekhaya   |     Iimveliso       |     SGS & UL Chiller       |     Ukupholisa Isisombululo     |     Inkampani      |    Umthombo       |      Uzinzo
Ilungelo lokushicilela © 2026 TEYU S&A Chiller | Imephu yesiza Umgaqo-nkqubo wabucala
Qhagamshelana nathi
email
Nxibelelana nenkonzo yabathengi
Qhagamshelana nathi
email
rhoxisa
Customer service
detect