afakwe imisebenzi eminingi ye-alamu ezenzakalelayo ukuqinisekisa ukuphepha kokukhiqiza. Uma ubhekene ne-alamu yezinga loketshezi le-E9, ungakuhlonza kanjani ngokushesha nangokunembile futhi ukuxazulule lokhu
inkinga yokuphola
?
1. Izimbangela Ze-E9 Liquid Level Alamu kuma-Industrial Chillers
I-alamu yeleveli yoketshezi engu-E9 ngokuvamile ibonisa ileveli yoketshezi engavamile ku-chiller yemboni. Izimbangela ezingenzeka zihlanganisa:
Izinga lamanzi aphansi:
Uma izinga lamanzi ku-chiller liwela ngaphansi komkhawulo obuncane obumisiwe, iswishi yeleveli icupha i-alamu.
Ukuvuza kwamapayipi:
Kungase kube khona ukuvuza endaweni yokungena, yokukhipha, noma amapayipi amanzi angaphakathi e-chiller, okubangela izinga lamanzi lehle kancane kancane.
Iswishi yeleveli enephutha:
I-level switch ngokwayo ingase ingasebenzi kahle, okuholela kuma-alamu amanga noma ama-alamu aphuthelwe.
![Causes and Solutions for E9 Liquid Level Alarm on Industrial Chiller Systems]()
2. Ukuxazulula izinkinga kanye nezixazululo ze-E9 Liquid Level Alamu
Ukuze uhlonze ngokunembile imbangela ye-alamu yezinga loketshezi le-E9, landela lezi zinyathelo ukuze uhlole futhi uthuthukise izixazululo ezihambisanayo:
Hlola izinga lamanzi:
Qala ngokubheka ukuthi ingabe izinga lamanzi ku-chiller lingaphakathi kwebanga elivamile. Uma izinga lamanzi liphansi kakhulu, engeza amanzi ezingeni elishiwo. Lesi yisixazululo esiqonde kakhulu.
Hlola ukuvuza:
Misa okokubandayo kumodi yokuzihambisa bese uxhuma ngokuqondile indawo yokungena amanzi endaweni ukuze ubone kangcono ukuvuza. Hlola ngokucophelela umsele, amapayipi endaweni yokungena nokuphuma kwepompo lamanzi, kanye nemigqa yangaphakathi yamanzi ukuze ubone noma yiziphi izindawo ezingavuza. Uma kutholakala ukuvuza, shisela futhi ukulungise ukuze ugweme ukuwohloka okwengeziwe ezingeni lamanzi. Ithiphu: Kunconywa ukuthi ufune usizo lokukhanda lochwepheshe noma uxhumane nesevisi yangemuva kokuthengisa. Njalo hlola amapayipi e-chiller namasekhethi amanzi ukuze uvimbele ukuvuza futhi ugweme ukucupha i-alamu yeleveli yoketshezi engu-E9.
Hlola isimo sokushintsha ileveli:
Okokuqala, qinisekisa ukuthi izinga langempela lamanzi ku-chiller yamanzi liyahlangabezana nezinga elijwayelekile. Bese, hlola inkinobho yeleveli ku-evaporator kanye nezintambo zayo. Ungenza ukuhlolwa kwe-short-circuit usebenzisa ucingo—uma i-alamu inyamalala, ukushintshwa kwezinga kunephutha. Bese ushintsha noma ulungise inkinobho yeleveli ngokushesha, futhi uqinisekise ukusebenza okulungile ukuze ugweme ukulimaza ezinye izingxenye.
![Causes and Solutions for E9 Liquid Level Alarm on Industrial Chiller Systems]()
Uma kuvela i-alamu yezinga loketshezi le-E9, landela lezi zinyathelo ezingenhla ukuze uxazulule futhi uxazulule inkinga. Uma inkinga isenzima, ungazama ukuxhumana ne-
ithimba lobuchwepheshe lomkhiqizi we-chiller
noma ubuyisele i-industrial chiller ukuze ilungiswe.