loading
Ulimi

Kungani i-CW-5200TITY-UL iyisinqumo se-Industrial Chiller esingabizi kakhulu eNyakatho Melika

Thola ukuthi kungani i-TEYU CW-5200TITY-UL iyi-chiller yezimboni engabizi kakhulu eNyakatho Melika, inikeza ukuphepha okubhalwe ku-UL, ukuzinza kwe-±0.3°C, ukuhambisana kwe-220–240V 50/60Hz, kanye ne-R-1234yf.

Kwimishini yezimboni ekhonza izimakethe zase-US naseCanada, ukukhetha i-chiller kungaphezu nje kwamandla okupholisa. Isitifiketi sokuphepha, ukuhambisana kukagesi, ukuzinza kwezinga lokushisa, ukukhethwa kwe-refrigerant, kanye nenani eliphelele kuyizinto ezibalulekile kakhulu.
TEYU I-CW-5200TITY-UL ihlanganisa lezi zici ndawonye ku- i- compact industrial chiller . Ngesitifiketi esifakwe ohlwini lwe-UL, ukuzinza kokushisa okungu-±0.3°C, umthamo wokupholisa ongu-1.77 kW / 2.08 kW, ukuhambisana kwamandla okungu-220–240V 50/60Hz, kanye ne-refrigerant ephansi ye-R-1234yf GWP, inikeza ibhalansi eqinile yokusebenza kanye nenani lokutshalwa kwezimali emakethe yaseNyakatho Melika.

Kungani i-CW-5200TITY-UL iyisinqumo senani eliqinile?
A umshini wokuphola wezimboni ongabizi kakhulu akuyona ngempela inketho ebiza kancane. Inketho engcono yileyo enikeza amandla okupholisa, ukulawula, ukuvikela, isitifiketi, kanye nokuhambisana uhlelo lokusebenza olukudingayo ngempela ngaphandle kokukhulisa ngokweqile okungadingekile.
TEYU I-CW-5200TITY-UL yakhelwe ngaleli bhalansi. Umthamo wayo wokupholisa ongu-1.77 kW / 2.08 kW, kanye nokuqina kokushisa okungu-±0.3°C, inikeza ukupholisa okulawulwayo kwemishini edinga ukususwa kokushisa okuthembekile kanye nezimo zokupholisa ezizinzile.
Lokhu kwenza kube inketho ewusizo yezinhlelo zokusebenza ezidinga ukuqandisa okusebenzayo kanye nokulawulwa okunembile kokushisa ngaphandle kokuthuthela ngqo kumshini wokuphola wezimboni onamandla amakhulu.

 I-Industrial Chiller CW-5200TITY efakwe ohlwini lwe-UL

I-UL Ifakwe Kuhlu Lwezicelo ZaseNyakatho Melika
Kumakhasimende athenga imishini yezimakethe zase-US naseCanada, isitifiketi sokuphepha singaba yingxenye ebalulekile yokukhetha i-chiller.
TEYU I-CW-5200TITY-UL ibhalwe ku-UL, inikeza ukuzethemba okwengeziwe lapho icacisa imishini yokupholisa yezinhlelo zokusebenza zaseNyakatho Melika. Imininingwane yayo yamandla ye-AC 1P 220–240V, 50/60Hz iphinde isekele ukucushwa kwemishini yesigaba esisodwa okuhambisanayo ngenkathi ivumela kokubili izindawo zokusebenza ze-50Hz kanye ne-60Hz.
Ndawonye, ​​ukufakwa ohlwini lwe-UL kanye nemininingwane kagesi ehambisanayo kwenza i-TEYU CW-5200TITY-UL ibe ukukhetha okusebenzayo kwemishini ehloselwe imakethe yaseNyakatho Melika.

R-1234yf Yendawo Eshintshayo Yefriji
Ukukhethwa kweziqandisi kuya ngokuya kufaneleka njengoba imithethonqubo yezemvelo kanye nezidingo ze-GWP ephansi ziqhubeka nokuthonya imboni yeziqandisi.
TEYU I-CW-5200TITY-UL isebenzisa i-R-1234yf, i-refrigerant ephansi ye-GWP ehambisana noshintsho oluqhubekayo lwemboni oluya ezixazululweni ze-refrigerant ephansi ye-GWP.
Kumakhasimende ahlela ukuthenga imishini yeminyaka ezayo, ukukhetha i-chiller yezimboni enokulungiswa kwe-refrigerant okuphansi kwe-GWP kungaba yinto ewusizo yokuyicabangela kanye nokusebenza kokupholisa kanye nesitifiketi.

±0.3°C Ukuqina Kwezinga Lokushisa Nokulawula Okusebenzayo
TEYU I-CW-5200TITY-UL inikeza ukuzinza kokushisa okungu-±0.3°C ukusiza ukugcina izimo zokushisa ezihambisanayo zemishini ezwela ukushisa.
Abasebenzisi bangakhetha phakathi kwalokhu:
* Imodi yokushisa engaguquki yokugcina izinga lokushisa eliqondile lokupholisa.
* Imodi yokulawula ehlakaniphile yokulungisa ukusebenza kokupholisa ngokwezimo zokusebenza.
I-chiller ihlanganisa nemisebenzi eminingi ye-alamu nokuvikela, izibani zesibonakaliso sesimo esibomvu nesiluhlaza, kanye nesibonakaliso sezinga lamanzi sokuqapha okulula kwansuku zonke.
Ukuxhumana kwe-RS-485 Modbus RTU kusekela ukuhlanganiswa nezinhlelo zokwenza izinto ngokuzenzakalelayo kanye nokuqapha ezihambisanayo.

Ifanelekela Izicelo Ezihlukahlukene Zezimboni
TEYU I-CW-5200TITY-UL ayikhawulelwe kuhlelo lokusebenza olulodwa. Kuye ngomthwalo wangempela wokushisa wemishini kanye nezidingo zokupholisa, ingasetshenziswa ezinhlobonhlobo zemishini ezwela ukushisa, okuhlanganisa:
* Izinhlelo ze-laser ze-CO₂
* Amathuluzi omshini we-CNC
* Imishini yelabhorethri kanye neyokuhlaziya
* Eminye imishini yezimboni kanye neyokunemba edinga ukupholisa kabusha
Isihluthulelo sokukhetha kahle ukufanisa amandla okupholisa efriji, izinga lokushisa lefriji, ukugeleza, kanye nezinye izici nezidingo zangempela zemishini.

Ukukhetha Okubheke Phambili Kokupholisa Izimboni ZaseNyakatho Melika
Kumakhasimende aseNyakatho Melika, inani le-chiller yezimboni livela kakhulu ekuhlanganisweni kokusebenza, isitifiketi, ukuhambisana, ukukhethwa kwe-refrigerant, kanye nokusebenza kwesikhathi eside.
TEYU I-CW-5200TITY-UL ihlanganisa:
* Isitifiketi esibhalwe ku-UL
* Ukuhambisana kwamandla angu-220–240V, 50/60Hz
* ±0.3°C ukuzinza kwezinga lokushisa
* Umthamo wokupholisa ongu-1.77kW / 2.08 kW ku-50Hz / 60Hz
* Isiqandisi se-R-1234yf esiphansi se-GWP
* Ukulawula izinga lokushisa okuguquguqukayo kanye nemisebenzi yokuvikela
* Ukuxhumana kwe-RS-485 Modbus RTU
Ngezinhlelo zokusebenza ezidinga ukupholisa okuthembekile nosayizi ofanele, inikeza ibhalansi ekhangayo yokusebenza, ukusebenza okusebenzayo, kanye nenani eliphelele—okwenza kube inketho eqinile yezimboni zokupholisa okufanele icatshangelwe emakethe yaseNyakatho Melika.
Hlola TEYU Isitshizi sezimboni se-CW-5200TITY-UL ukuthola imininingwane eningiliziwe kanye nolwazi lokucushwa, noma xhumana no-TEYU nge-sales@teyuchiller.com ukuxoxa ngezidingo zakho zokupholisa.

 Umkhiqizi We-Industrial Chiller e-USA

Okwangaphambilini
Indlela Yokukhetha I-Chiller Efanele Yomshini Wokuhlanza I-Laser Ophathwa Ngesandla
Izinhlobo Zokushisisa Iphrinta Ye-3D: Yiziphi Izinhlobo Zokukhiqiza Ezifanele Ukucatshangelwa?
Olandelayo

Silapha ukuze sikusize uma usidinga.

Sicela ugcwalise ifomu ukuze usithinte, futhi sizojabula ukukusiza.

Ikhaya   |     Imikhiqizo       |     I-SGS & UL Chiller       |     Isixazululo Sokupholisa     |     Inkampani      |    Insiza       |      Ukusimama
Ilungelo Lokushicilela © 2026 TEYU S&A Chiller | Imephu Yesayithi Inqubomgomo Yobumfihlo
Xhumana nathi
email
Xhumana nenkonzo yamakhasimende
Xhumana nathi
email
hlikihla
Customer service
detect