TEYU CWFL-3000BNPTY-UL industrial chiller is engineered for 3–4kW fiber laser cutting and welding systems, providing dual independent cooling circuits to separately cool the laser source and optics. Independently tested by SGS to UL & CSA standards, it is designed to meet North American electrical safety requirements while supporting reliable operation in demanding industrial environments.


Featuring intelligent dual temperature control, RS-485 Modbus RTU communication, anti-condensation design and multi-level protection, TEYU CWFL-3000BNPTY-UL integrates easily with modern laser systems while helping maintain stable processing performance. Its compact design and dependable cooling make it an ideal solution for OEM laser equipment manufacturers, system integrators, and industrial metal fabrication applications.

Product characteristics

Product parameters

Model CWFL-3000BNPTY-UL Voltage AC 1P 220V
Frequency 60Hz Current 4.5-26.7A
Max. power consumption 6.4kW Heater power 800W+1800W
Nominal cooling capacity 31050Btu/h Refrigerant R-32
9.1kW Precision ±0.5℃
7824Kcal/h Rated flow Capillary
Pump power 1kW Tank capacity 40L
Inlet and outlet Rp1 /2” + Rp1” Max. pump pressure 4.6 bar
Rated flow 2L/min+>67L/min Dimension 87 × 65 × 117cm (L × W × H)
N.W. 135kg Package dimension 95 × 77 × 135cm (L × W × H)
G.W. 150kg    

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency stop available to instantly eliminate hazards
Emergency stop available to instantly eliminate hazards
Multiple warning protections: flow, temperature, and pressure...
Multiple warning protections: flow, temperature, and pressure...
Separate circuits for laser source and optics - improves system reliability
Separate circuits for laser source and optics - improves system reliability
RS-485 Modbus RTU for easy MES and factory automation integration
RS-485 Modbus RTU for easy MES and factory automation integration
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±0.5℃
Dual-circuit water connections
Designed for easy installation and maintenance
Waterproof junction box
Safe and stable, flexible power cable installation
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Water pressure gauge
Display of water pump status and water pressure
Heater
Increase water temperature and prevent condensation

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Home     |    Products     |    SGS & UL Chiller     |    Cooling Solution    |    Company     |    Resource     |    Sustainability
Copyright © 2026 TEYU S&A Chiller | Sitemap    Privacy policy
Contact us
email
Contact customer service
Contact us
email
cancel
Customer service
detect