loading
Language

SGS-Tested Industrial Process Chiller CW-6000BNPTY-UL

UL & CSA Compliant Precision Chiller for CO₂ Lasers and Industrial Equipment

TEYU CW-6000BNPTY-UL industrial chiller is a compact industrial process chiller designed for CO₂ laser systems, laboratory equipment, and precision industrial machinery requiring stable temperature control. Independently tested by SGS to UL & CSA standards, it is engineered to meet North American electrical safety requirements while delivering 3140W cooling capacity with ±0.5°C temperature stability.


Featuring intelligent temperature control modes, RS-485 Modbus RTU communication, a sealed electrical junction box, and multi-level protection, TEYU CW-6000BNPTY-UL provides dependable cooling for daily industrial operation. Its compact design and reliable performance make it an ideal solution for equipment manufacturers, laser processing systems, and precision production environments.

Product characteristics

Product parameters

Model CW-6000BNPTY-UL Voltage AC 1P 220~240V
Frequency 60Hz Current 1.7~6.1A
Max. power consumption 1.3kW Nominal cooling capacity 31050Btu/h
Compressor power 0.71kW 9.1kW
0.97HP 7824Kcal/h
Pump power 0.37kW Max. pump pressure 2.5 bar
Rated flow 33L/min Refrigerant R-32
Precision ±0.5℃ Reducer Capillary
Tank capacity 22L Inlet and outlet Rp1/2"
N.W. 74kg Dimension 87 × 65 × 117cm (L × W × H)
G.W. 85kg Package dimension 95 × 77 × 135cm (L × W × H)
 

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Home     |    Products     |    SGS & UL Chiller     |    Cooling Solution    |    Company     |    Resource     |    Sustainability
Copyright © 2026 TEYU S&A Chiller | Sitemap    Privacy policy
Contact us
email
Contact customer service
Contact us
email
cancel
Customer service
detect