CO2 Laser Chiller
VR
Product Introduction

Model: CW-3000

Machine Size: 49 X 27 X 38cm (L X W X H)

Warranty: 2 years

Standard: CE, REACH and RoHS

Product Parameters
ModelCW-3000TGCW-3000DGCW-3000TKCW-3000DK
VoltageAC 1P 220VAC 1P 110VAC 1P 220VAC 1P 110V
Frequency50/60Hz
Current0.4~1A0.4~0.9A0.3~0.9A0.3~0.8A

Max. power consumption

0.10kW0.11kW
Radiating capacity50W/℃

Max. pump pressure

10M70M

Max. pump flow

10L/min2L/min
N.W.9Kg8.7Kg12Kg
G.W.11Kg11 Kg15Kg
ProtectionFlow alarm
Tank capacity9L
Inlet and outletOD 10mm barbed connector8mm fast connector
Dimension49 X 27 X 38cm (L X W X H)
Package dimension55 X 34 X 43cm (L X W X H)

The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

Product Features

* Heat dissipation capacity: 50W/℃, meaning it can absorb 50W of heat by rising 1°C of water temperature;

* Passive cooling, no refrigerant

* High speed fan                                      

* 9L reservoir

* Digital temperature display

* Built-in alarm functions

* Easy operation and space-saving                                 

* Low energy and environmental

Optional Items

              

 Heater


               

Filter


              

 US standard plug / EN standard plug


Product Details
                                       

High speed fan


The high speed fan is installed to ensure high cooling performance.

                                       

Integrated top mounted handle


The firm handles are mounted on top for easy mobility.

                                       

Digital temperature display


The digital temperature display is able to indicate water temperature and alarm codes. 

Ventilation Distance

Certificate
Product Working Principle

FAQ
Is S&A Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
What is the ideal room temperature for the chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team ([email protected]) first.
Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

If You Have More Questions, Write To Us

Just leave your email or phone number on the contact form so we can provide you with more services!

Send your inquiry

Choose a different language
English English العربية العربية Deutsch Deutsch Español Español français français italiano italiano 日本語 日本語 한국어 한국어 Português Português русский русский 简体中文 简体中文 繁體中文 繁體中文 Afrikaans Afrikaans አማርኛ አማርኛ Azərbaycan Azərbaycan Беларуская Беларуская български български বাংলা বাংলা Bosanski Bosanski Català Català Sugbuanon Sugbuanon Corsu Corsu čeština čeština Cymraeg Cymraeg dansk dansk Ελληνικά Ελληνικά Esperanto Esperanto Eesti Eesti Euskara Euskara فارسی فارسی Suomi Suomi Frysk Frysk Gaeilgenah Gaeilgenah Gàidhlig Gàidhlig Galego Galego ગુજરાતી ગુજરાતી Hausa Hausa Ōlelo Hawaiʻi Ōlelo Hawaiʻi हिन्दी हिन्दी Hmong Hmong Hrvatski Hrvatski Kreyòl ayisyen Kreyòl ayisyen Magyar Magyar հայերեն հայերեն bahasa Indonesia bahasa Indonesia Igbo Igbo Íslenska Íslenska עִברִית עִברִית Basa Jawa Basa Jawa ქართველი ქართველი Қазақ Тілі Қазақ Тілі ខ្មែរ ខ្មែរ ಕನ್ನಡ ಕನ್ನಡ Kurdî (Kurmancî) Kurdî (Kurmancî) Кыргызча Кыргызча Latin Latin Lëtzebuergesch Lëtzebuergesch ລາວ ລາວ lietuvių lietuvių latviešu valoda‎ latviešu valoda‎ Malagasy Malagasy Maori Maori Македонски Македонски മലയാളം മലയാളം Монгол Монгол मराठी मराठी Bahasa Melayu Bahasa Melayu Maltese Maltese ဗမာ ဗမာ नेपाली नेपाली Nederlands Nederlands norsk norsk Chicheŵa Chicheŵa ਪੰਜਾਬੀ ਪੰਜਾਬੀ Polski Polski پښتو پښتو Română Română سنڌي سنڌي සිංහල සිංහල Slovenčina Slovenčina Slovenščina Slovenščina Faasamoa Faasamoa Shona Shona Af Soomaali Af Soomaali Shqip Shqip Српски Српски Sesotho Sesotho Sundanese Sundanese svenska svenska Kiswahili Kiswahili தமிழ் தமிழ் తెలుగు తెలుగు Точики Точики ภาษาไทย ภาษาไทย Pilipino Pilipino Türkçe Türkçe Українська Українська اردو اردو O'zbek O'zbek Tiếng Việt Tiếng Việt Xhosa Xhosa יידיש יידיש èdè Yorùbá èdè Yorùbá Zulu Zulu
Current language:English
Send Your Inquiry