loading
Iaith

Oerydd laser ffibr SGS-Profi CWFL-40000KTPTY-UL

Oerydd Diwydiannol sy'n Cydymffurfio ag UL a CSA ar gyfer Systemau Laser Ffibr Pŵer Uchel Iawn 40kW

TEYU Mae oerydd diwydiannol CWFL-40000KTPTY-UL wedi'i gynllunio ar gyfer systemau laser ffibr pŵer uwch-uchel 40kW y genhedlaeth nesaf, gan ddarparu capasiti oeri o 85kW gyda chylchedau oeri annibynnol deuol ar gyfer rheolaeth thermol fanwl gywir a dibynadwy. Wedi'i brofi'n annibynnol gan SGS i safonau UL a CSA, mae'n cefnogi gofynion trydanol Gogledd America ar gyfer y cymwysiadau laser diwydiannol mwyaf heriol.


Gan gynnwys rheolaeth tymheredd deuol ddeallus, cyfathrebu RS-485 Modbus RTU, dyluniad gwrth-gyddwysiad, switsh stopio brys, ac amddiffyniad aml-lefel cynhwysfawr, mae CWFL-40000KTPTY-UL wedi'i adeiladu ar gyfer gweithrediad parhaus mewn amgylcheddau gweithgynhyrchu uwch. Mae'n ddatrysiad oeri delfrydol ar gyfer torri laser pŵer uwch-uchel, prosesu metel fformat mawr, a chynhyrchu diwydiannol y genhedlaeth nesaf sy'n gofyn am y sefydlogrwydd, yr effeithlonrwydd a'r dibynadwyedd hirdymor mwyaf posibl.

Product characteristics

Product parameters

ModelCWFL-40000KTPTY-UL FolteddAC 3P 460~480V
Amlder 60Hz Cyfredol10.2~75.5A
Defnydd pŵer uchaf 51.9kW Pŵer gwresogydd12000W+1800W
Capasiti oeri enwol 290032Btu/awr OergellR-32
85kW Manwldeb ±1℃
73100Kcal/awr Lleihawr Capilari
Pŵer pwmp 6kW Capasiti'r tanc340L
Mewnfa ac allfa Rp1/2"+Rp2” Pwysedd pwmp uchaf 6.5 bar
Llif graddedig 5L/mun + >300L/mun Dimensiwn 273 × 96 × 150cm (H × L × U)
N.W. 620kg Dimensiwn y pecyn 287 × 120 × 175cm (H × L × U)
G.W. 826kg

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop available to instantly eliminate hazards
Emergency Stop: available to instantly eliminate hazards
Multiple warning protections: flow, temperature, level, and pressure...
Multiple warning protections: flow, temperature, level, and pressure...
Thermal insulation for water tubing, pump and evaporator.
Thermal insulation for water tubing, pump and evaporator.
RS-485 Modbus RTU for easy MES and factory automation integration.
RS-485 Modbus RTU for easy MES and factory automation integration.
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Dual-circuit water connections
Designed for easy installation and maintenance
Water pressure gauge
Display of water pump status and water pressure
Easy-to-read water level indicator
Yellow area - high water level.
Green area - normal water level.
Red area - low water level.
Three premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Cartref   |     Cynhyrchion       |     Oerydd SGS ac UL       |     Datrysiad Oeri     |     Cwmni      |    Adnodd       |      Cynaliadwyedd
Hawlfraint © 2026 Oerydd TEYU S&A | Map o'r Wefan Polisi Preifatrwydd
Cysylltwch â ni
email
Cysylltwch â Gwasanaeth Cwsmeriaid
Cysylltwch â ni
email
ganslo
Customer service
detect