SGS-Hoʻāʻo ʻia ka fiber Laser Chiller CWFL-40000KTPTY-UL

ʻO ka Chiller ʻoihana e kūlike me UL & CSA no nā ʻōnaehana laser fiber mana kiʻekiʻe 40kW

TEYU Ua hoʻolālā ʻia ka chiller ʻoihana CWFL-40000KTPTY-UL no nā ʻōnaehana laser fiber mana kiʻekiʻe 40kW o ka hanauna e hiki mai ana, e hāʻawi ana i ka hiki ke hoʻoluʻu 85kW me nā kaapuni hoʻoluʻu kūʻokoʻa ʻelua no ka hoʻokele wela pololei a hilinaʻi hoʻi. Hoʻāʻo kūʻokoʻa ʻia e SGS i nā kūlana UL & CSA, kākoʻo ia i nā koi uila ʻAmelika ʻĀkau no nā noi laser ʻoihana koi nui loa.


Me ka mana hoʻomalu mahana pālua akamai, ka kamaʻilio RS-485 Modbus RTU, ka hoʻolālā anti-condensation, kahi kuapo hoʻōki ulia pōpilikia, a me ka pale piha multi-level, ua kūkulu ʻia ʻo CWFL-40000KTPTY-UL no ka hana mau ʻana i nā wahi hana holomua. He hopena hoʻoluʻu kūpono ia no ka ʻoki ʻana i ka laser mana kiʻekiʻe loa, ka hana ʻana i ka metala nui, a me ka hana ʻoihana hanauna hou e koi ana i ka paʻa loa, ka pono, a me ka hilinaʻi lōʻihi.

Product characteristics

Product parameters

HoʻohālikeCWFL-40000KTPTY-UL Uila uilaAC 3P 460~480V
Alapine (frequency) 60Hz I kēia manawa10.2~75.5A
Ka hoʻohana ʻana i ka mana kiʻekiʻe loa 51.9kW Mana hoʻomehana12000W+1800W
Ka mana hoʻoluʻu maʻamau 290032Btu/h Mea hoʻomaʻaliliR-32
85kW Pololei ±1℃
73100Kcal/h Mea hoʻēmi Kapila
Mana o ka pauma 6kW Ka nui o ka pahu wai340L
Ka puka komo a me ka puka waho Rp1/2"+Rp2” Kaomi pauma kiʻekiʻe loa 6.5 pā
Kahe i helu ʻia 5L/min+>300L/min Ana 273 × 96 × 150 kenimika (L × W × H)
N.W. 620kg Ana o ka pūʻolo 287 × 120 × 175 kenimika (L × W × H)
G.W. 826kg

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop available to instantly eliminate hazards
Emergency Stop: available to instantly eliminate hazards
Multiple warning protections: flow, temperature, level, and pressure...
Multiple warning protections: flow, temperature, level, and pressure...
Thermal insulation for water tubing, pump and evaporator.
Thermal insulation for water tubing, pump and evaporator.
RS-485 Modbus RTU for easy MES and factory automation integration.
RS-485 Modbus RTU for easy MES and factory automation integration.
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Dual-circuit water connections
Designed for easy installation and maintenance
Water pressure gauge
Display of water pump status and water pressure
Easy-to-read water level indicator
Yellow area - high water level.
Green area - normal water level.
Red area - low water level.
Three premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Home   |     Nā huahana       |     SGS & UL Chiller       |     Hoʻonā ʻoluʻolu     |     Hui      |    Punawai       |      Hoʻomau
Kuleana kope © 2026 TEYU S&A Chiller | Palapala ʻāina Kulekele pilikino
Kāhea iā mā ˚ ou
email
Hōʻike i ka lawelawe kūʻai aku
Kāhea iā mā ˚ ou
email
Ke kāpae nei
Customer service
detect