SGS-Lekoa fiber Laser Chiller CWFL-40000KTPTY-UL

Chiller ea Liindasteri e Latelang UL & CSA bakeng sa Sistimi ea Laser ea Faeba ea Matla a Phahameng ea 40kW

TEYU CWFL-40000KTPTY-UL industrial chiller e etselitsoe litsamaiso tsa laser ea fiber ea moloko o latelang ea 40kW ultra-high-power, e fanang ka bokhoni ba ho pholisa ba 85kW ka lipotoloho tse peli tse ikemetseng tsa ho pholisa bakeng sa taolo e nepahetseng le e tšepahalang ea mocheso. E lekoa ka boikemelo ke SGS ho ea ho maemo a UL le CSA, e tšehetsa litlhoko tsa motlakase tsa Amerika Leboea bakeng sa lits'ebetso tsa laser ea indasteri tse hlokang boiteko bo boholo.


E na le taolo e bohlale ea mocheso o habeli, puisano ea RS-485 Modbus RTU, moralo o thibelang ho kolobisoa ha mocheso, switch ea ho emisa ea tšohanyetso, le tšireletso e felletseng ea maemo a mangata, CWFL-40000KTPTY-UL e hahiloe bakeng sa ts'ebetso e tsoelang pele libakeng tse tsoetseng pele tsa tlhahiso. Ke tharollo e phethahetseng ea ho pholisa bakeng sa ho seha laser ka matla a phahameng haholo, ts'ebetso ea tšepe ea sebopeho se seholo, le tlhahiso ea indasteri ea moloko o latelang e hlokang botsitso bo phahameng, bokhoni, le ts'epo ea nako e telele.

Product characteristics

Product parameters

MohlalaCWFL-40000KTPTY-UL Palo ea li-voltsAC 3P 460~480V
Maqhubu 60Hz Hona joale10.2~75.5A
Tšebeliso e phahameng ka ho fetisisa ea matla 51.9kW Matla a hitara12000W+1800W
Bokhoni ba ho pholisa bo ikgethang 290032Btu/h SehatsetsingR-32
85kW Ho nepahala ±1℃
73100Kcal/h Sefokotsi Mothapo oa mali
Matla a pompo 6kW Bokhoni ba tanka340L
Monyako le sehokelo Rp1/2"+Rp2” Khatello e phahameng ea pompo Bara ea 6.5
Phallo e lekantsoe 5L/motsotso+ >300L/motsotso Tekanyo 273 × 96 × 150cm (L × Bophara × Bophahamo)
N.W. 620kg Tekanyo ea sephutheloana 287 × 120 × 175cm (Bophara × Bophara × Bophahamo)
G.W. 826kg

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop available to instantly eliminate hazards
Emergency Stop: available to instantly eliminate hazards
Multiple warning protections: flow, temperature, level, and pressure...
Multiple warning protections: flow, temperature, level, and pressure...
Thermal insulation for water tubing, pump and evaporator.
Thermal insulation for water tubing, pump and evaporator.
RS-485 Modbus RTU for easy MES and factory automation integration.
RS-485 Modbus RTU for easy MES and factory automation integration.
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Dual-circuit water connections
Designed for easy installation and maintenance
Water pressure gauge
Display of water pump status and water pressure
Easy-to-read water level indicator
Yellow area - high water level.
Green area - normal water level.
Red area - low water level.
Three premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Lehae   |     Lihlahisoa       |     SGS & UL Chiller       |     Tharollo ea ho Pholisa     |     Khampani      |    Mohlodi       |      Moshoelella
Tokelo ea Mongoli © 2026 TEYU S&A Chiller | 'Mapa oa Sebaka Leano la Lekunutu
Iteanye le rona
email
Ikopanye le ts'ebeletso ea bareki
Iteanye le rona
email
hlakola
Customer service
detect