TEYU Chiller industri CWFL-40000KTPTY-UL dirancang pikeun sistem laser serat kakuatan ultra-luhur 40kW generasi salajengna, nganteurkeun kapasitas pendinginan 85kW kalayan sirkuit pendinginan mandiri ganda pikeun manajemen termal anu tepat sareng tiasa dipercaya. Diuji sacara mandiri ku SGS numutkeun standar UL & CSA, éta ngadukung sarat listrik Amérika Kalér pikeun aplikasi laser industri anu paling nungtut.


Dilengkepan kontrol suhu ganda anu calakan, komunikasi RS-485 Modbus RTU, desain anti-kondensasi, saklar eureun darurat, sareng panyalindungan multi-tingkat anu komprehensif, CWFL-40000KTPTY-UL didamel pikeun operasi kontinyu dina lingkungan manufaktur canggih. Éta mangrupikeun solusi pendinginan anu idéal pikeun motong laser kakuatan ultra-luhur, pamrosésan logam format ageung, sareng produksi industri generasi salajengna anu meryogikeun stabilitas, efisiensi, sareng reliabilitas jangka panjang anu maksimal.

Product characteristics

Product parameters

ModélCWFL-40000KTPTY-UL VoltaseuAC 3P 460~480V
Frékuénsi 60Hz Ayeuna10.2~75.5A
Konsumsi daya maksimal 51.9kW Kakuatan pemanas12000W+1800W
Kapasitas pendinginan nominal 290032Btu/jam RefrigeranR-32
85kW Presisi ±1℃
73100Kkal/jam Pangurang Kapiler
Kakuatan pompa 6kW Kapasitas tangki340L
Asupan sareng kaluaran Rp1/2"+Rp2” Tekanan pompa maks. 6,5 bar
Aliran anu dipeunteun 5L/mnt+>300L/mnt Diménsi 273 × 96 × 150cm (P × L × T)
N.W. 620 kg Diménsi pakét 287 × 120 × 175cm (P × L × T)
G.W. 826 kg

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop available to instantly eliminate hazards
Emergency Stop: available to instantly eliminate hazards
Multiple warning protections: flow, temperature, level, and pressure...
Multiple warning protections: flow, temperature, level, and pressure...
Thermal insulation for water tubing, pump and evaporator.
Thermal insulation for water tubing, pump and evaporator.
RS-485 Modbus RTU for easy MES and factory automation integration.
RS-485 Modbus RTU for easy MES and factory automation integration.
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Dual-circuit water connections
Designed for easy installation and maintenance
Water pressure gauge
Display of water pump status and water pressure
Easy-to-read water level indicator
Yellow area - high water level.
Green area - normal water level.
Red area - low water level.
Three premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Imah   |     Produk       |     SGS & UL Chiller       |     Solusi cooling     |     Perusahaan      |    Sumberdaya       |      Kelestarian
Hak Cipta © 2026 TEYU S&A Chiller | Peta Situs Kawijakan privasi
Taros Kami
email
Palayanan Pelanggan
Taros Kami
email
ngabatalkeun
Customer service
detect