loading
Lang

Refwadisè Pwosesis Endistriyèl CW-6260BNPTY-UL ki teste pa SGS

Refwadisè Pwosesis Gwo Kapasite Konfòm UL ak CSA pou Sistèm Refwadisman Endistriyèl

TEYU Refwadisè endistriyèl CW-6260BNPTY-UL la fèt pou ekipman endistriyèl ki gen pi gwo demand pou refwadisman, li bay yon kapasite refwadisman 9000W ak yon estabilite tanperati ±0.5°C pou yon refwadisman pwosesis kontinyèl. Li teste endepandamman pa SGS selon estanda UL ak CSA yo, epi li fèt pou satisfè egzijans sekirite elektrik Amerik di Nò pou anviwònman endistriyèl ki mande anpil.


Avèk mòd kontwòl tanperati entelijan, kominikasyon RS-485 Modbus RTU, yon bwat koneksyon elektrik sele, siveyans presyon febrifuj, ak pwoteksyon konplè sou plizyè nivo, TEYU CW-6260BNPTY-UL bay pèfòmans serye pou pwosesis endistriyèl ki gen gwo chaj. Li se yon ekselan chwa pou sistèm lazè CO₂ gwo puisans, machin CNC, fabrikasyon endistriyèl, ak lòt aplikasyon ki mande refwadisman serye alontèm.

Product characteristics

Product parameters

ModèlCW-6260BNPTY-UL VòltajAC 1P 220~240V
Frekans 60Hz Kouran5.4~20.5A
Konsomasyon maksimòm pouvwa 4.5kW Kapasite refwadisman nominal 30708Btu/èdtan
Pouvwa konpresè 3.02kW 9kW
4.11HP 7738Kcal/èdtan
Pouvwa ponp 1kW Presyon ponp maksimòm 4.6 ba
Koule nominal 67L/min FrijidèR-32
Presizyon ±0.5℃ Rediktè Kapilè
Kapasite tank40L Antre ak sòti Rp1"
N.W. 135kg Dimansyon 87 × 65 × 118cm (L × La × Wotè)
G.W. 153kg Dimansyon pake a 95 × 77 × 135cm (L × La × Wotè)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Lakay   |     Pwodwi yo       |     Refwadisè SGS ak UL       |     Solisyon Refwadisman     |     Konpayi      |    Resous       |      Dirablite
Dwa otè © 2026 TEYU S&A Refwadisè | Règleman sou enfòmasyon prive
Kontakte nou
email
Kontakte Sèvis Kliyan
Kontakte nou
email
anile
Customer service
detect