loading
Wika

Industrial Process Chiller na Sinubukan ng SGS CW-6260BNPTY-UL

UL & CSA Compliant High-Capacity Process Chiller para sa mga Industrial Cooling System

TEYU Ang CW-6260BNPTY-UL industrial chiller ay ginawa para sa mga kagamitang pang-industriya na may mas mataas na pangangailangan sa pagpapalamig, na nagbibigay ng 9000W na kapasidad sa pagpapalamig at ±0.5°C na katatagan ng temperatura para sa patuloy na pagpapalamig ng proseso. Malayang sinubukan ng SGS ayon sa mga pamantayan ng UL at CSA, ito ay dinisenyo upang matugunan ang mga kinakailangan sa kaligtasan ng kuryente sa Hilagang Amerika para sa mga mahihirap na kapaligirang pang-industriya.


Nagtatampok ng mga intelligent temperature control mode, RS-485 Modbus RTU communication, isang selyadong electrical junction box, refrigerant pressure monitoring, at komprehensibong multi-level protection, ang TEYU CW-6260BNPTY-UL ay naghahatid ng maaasahang performance para sa mga high-load industrial processes. Ito ay isang mahusay na pagpipilian para sa mga high-power CO₂ laser system, CNC machining, industrial manufacturing, at iba pang mga aplikasyon na nangangailangan ng maaasahang pangmatagalang pagpapalamig.

Product characteristics

Product parameters

ModeloCW-6260BNPTY-UL BoltaheAC 1P 220~240V
Dalas 60Hz Kasalukuyan5.4~20.5A
Pinakamataas na pagkonsumo ng kuryente 4.5kW Nominal na kapasidad ng paglamig 30708Btu/oras
Lakas ng compressor 3.02kW 9kW
4.11HP 7738Kcal/oras
Lakas ng bomba 1kW Pinakamataas na presyon ng bomba 4.6 bar
Na-rate na daloy 67L/min PampalamigR-32
Katumpakan ±0.5℃ Pampabawas Kapilar
Kapasidad ng tangke40L Pasok at labasan Rp1"
N.W. 135kg Dimensyon 87 × 65 × 118cm (P × L × T)
G.W. 153kg Dimensyon ng pakete 95 × 77 × 135cm (P × L × T)

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Emergency Stop: Quick shutdown to prevent hazards and ensure operational safety.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Multi-Level Protection: Flow and temperature monitoring minimizes unexpected downtime.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Dual Temperature Control Modes: Flexible switching delivers stable and efficient cooling performance.
Smart Communication: RS-485 Modbus RTU simplifies MES and automation integration.
Smart Communication: RS-485 Modbus RTU enables seamless MES and automation integration.
Precise temperature control
±0.5°C precision helps maintain stable laser performance during continuous operation.
Easy water level monitoring
Three-color indicator clearly shows high, normal, and low water levels.
Sealed electrical junction box
Enhances wiring safety and installation flexibility in industrial environments.
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Bahay   |     Mga produkto       |     SGS at UL Chiller       |     Solusyon sa Paglamig     |     kumpanya      |    mapagkukunan       |      Sustainability
Karapatang-ari © 2026 TEYU S&A Chiller | Patakaran sa privacy
Makipag-ugnayan sa amin
email
Makipag -ugnay sa Serbisyo sa Customer
Makipag-ugnayan sa amin
email
Kanselahin
Customer service
detect