loading
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser
Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser

Industrial Cooling System CWFL-20000 for 20kW High Performance Fiber Laser

Industrial cooling system CWFL-20000 is designed to offer advanced features while also making 20KW fiber laser cooling easier and more efficient. With dual refrigeration circuit, this recirculating water chiller system has enough capacity to cool the fiber laser and the optics independently and simultaneously. All of the components are carefully selected to ensure reliable operation. A smart temperature controller is installed with advanced software to optimize the chiller's performance. The refrigerant circuit system adopts solenoid valve bypass technology to avoid frequent start and stop of the compressor to prolong its service life. RS-485 interface is provided for communication with the fiber laser system.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Industrial Cooling System CWFL-20000 for 20KW High Performance Fiber Laser

    Model: CWFL-20000

    Machine Size: 158X80X132cm (L x W x H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    Model CWFL-20000ETS04 CWFL-20000FTS04
    Voltage AC 3P 380V AC 3P 380V
    Frequency 50Hz 60Hz
    Current 5.3~47.2A 6~43.7A
    Max. power consumption 28.86kW 24.4kW
    Heater power 1000W+7500W
    Precision ±1.5℃
    Reducer Capillary
    Pump power 3.5kW 3kW
    Tank capacity 170L
    Inlet and outlet Rp1/2"+ Rp1-1/2"
    Max. pump pressure 8.5bar 5.8bar
    Rated flow 5L/min+>150L/min
    N.W. 315Kg 311Kg
    G.W. 357Kg 353Kg
    Dimension 158X80X132cm (L x W x H)
    Package dimension 170X93X152cm (L x W x H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product

    Product Features

    * Dual cooling circuit

    * Active cooling

    * Temperature stability: ±1.5°C

    * Temperature control range: 5°C ~35°C

    * Refrigerant: R-410A

    * Intelligent digital control panel

    * Integrated alarm functions

    * Back mounted fill port and easy-to-read water level check                                       

    * RS-485 Modbus communication function

    * High reliability, energy efficiency and durability

    * Available in 380V

    * Available in SGS-certified version, equivalent to UL standard.

    Optional Items

                  

     Heater

     

                   

    Filter

     

    Product Details
    S&A CWFL-20000 Laser Chiller Temperature Controller
                                           

    Dual temperature control

     

    The intelligent control panel offers two independent temperature control systems. One is for controlling the temperature of the fiber laser and the other is for controlling the optics.

    S&A CWFL-20000 Laser Chiller Water Inlet and Water Outlet
                                           

    Dual water inlet and water outlet

     

    Water inlets and water outlets are made from stainless steel to prevent potential corrosion or water leakage.

    S&A Laser Chiller Drain Port With Valve
                                           

    Easy drain port with valve

     

    Draining process can be controlled very easily.

    Ventilation Distance

    Industrial Water Chiller Ventilation Distance

    Certificate
    S&A Industrial Water Chiller Certificate
    Product Working Principle

    S&A Laser Chiller CWFL-20000 Working Principle

    FAQ
    Is S&A Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect