loading
Products
VR
Product Introduction
Industrial Chiller Unit CW-6500 for CO2 Laser Cutting Machine

Model: CW-6500

Machine Size: 83 X 65 X 117cm (LX W X H)

Warranty: 2 years

Standard: CE, REACH and RoHS

Product Parameters
ModelCW-6500ENCW-6500FN
VoltageAC 3P 380VAC 3P 380V
Frequency50Hz60Hz
Current1.4~16.6A2.1~16.5A

Max. power consumption

7.55kW8.25kW


Compressor power

4.6kW5.12kW
6.16HP6.86HP



Nominal cooling capacity

51880Btu/h
15kW
12897Kcal/h
Pump power0.55kW1kW

Max. pump pressure

4.4bar5.9bar

Max. pump flow

75L/min130L/min
RefrigerantR-410a
Precision±1℃
ReducerCapillary
Tank capacity40L
Inlet and outletRp1"
N.W124Kg
G.W146Kg
Dimension83 X 65 X 117 cm (LX W X H)
Package dimension95 X 77 X 135 cm (LX W X H)

The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

Product Features

* Cooling Capacity: 15000W

* Active cooling

* Temperature stability: ±1°C

* Temperature control range: 5°C ~35°C

* Refrigerant: R-410a

* Intelligent temperature controller

* Multiple alarm functions                             

* Ready for immediate use                             

* Easy maintenance and mobility

* RS-485 Modbus communication function

* Available in 380V


Optional Items

              

 Heater


               

Filter


Product Details
Industrial Water Chiller Unit CW-6500 Intelligent Temperature Controller
                                       

Intelligent temperature controller


The temperature controller offers high precision temperature control of ±1°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode.

Laser Chiller Unit CW-6500 Water Level Indicator
                                       

Easy-to-read water level indicator


The water level indicator has 3 color areas - yellow, green and red.


Yellow area - high water level.

Green area - normal water level.

Red area - low water level.  

CO2 Laser Chiller Unit CW-6500 Caster Wheels
                                       

Caster wheels for easy mobility


Four caster wheels offer easy mobility and unmatched flexibility.

Ventilation Distance

Industrial Water Chiller CW-6500 Ventilation Distance

Certificate
CO2 Laser Cutting Machine Chiller Certificate
Product Working Principle

CO2 Laser Cutting Machine Chiller Product Working Principle

FAQ
Is S&A Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
What is the ideal room temperature for the chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team ([email protected]) first.
Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

If You Have More Questions, Write To Us

Just leave your email or phone number on the contact form so we can provide you with more services!

Send your inquiry

Choose a different language
English
العربية
Deutsch
Español
français
italiano
日本語
한국어
Português
русский
简体中文
繁體中文
Afrikaans
አማርኛ
Azərbaycan
Беларуская
български
বাংলা
Bosanski
Català
Sugbuanon
Corsu
čeština
Cymraeg
dansk
Ελληνικά
Esperanto
Eesti
Euskara
فارسی
Suomi
Frysk
Gaeilgenah
Gàidhlig
Galego
ગુજરાતી
Hausa
Ōlelo Hawaiʻi
हिन्दी
Hmong
Hrvatski
Kreyòl ayisyen
Magyar
հայերեն
bahasa Indonesia
Igbo
Íslenska
עִברִית
Basa Jawa
ქართველი
Қазақ Тілі
ខ្មែរ
ಕನ್ನಡ
Kurdî (Kurmancî)
Кыргызча
Latin
Lëtzebuergesch
ລາວ
lietuvių
latviešu valoda‎
Malagasy
Maori
Македонски
മലയാളം
Монгол
मराठी
Bahasa Melayu
Maltese
ဗမာ
नेपाली
Nederlands
norsk
Chicheŵa
ਪੰਜਾਬੀ
Polski
پښتو
Română
سنڌي
සිංහල
Slovenčina
Slovenščina
Faasamoa
Shona
Af Soomaali
Shqip
Српски
Sesotho
Sundanese
svenska
Kiswahili
தமிழ்
తెలుగు
Точики
ภาษาไทย
Pilipino
Türkçe
Українська
اردو
O'zbek
Tiếng Việt
Xhosa
יידיש
èdè Yorùbá
Zulu
Current language:English