SGS-Teste Fiber Laser Chiller CWFL-15000KNPTY-UL

UL & CSA konform Industriekillmaschinn fir 12kW-15kW Glasfaserlaserschneiden & Fabrikatioun

TEYU Den industrielle Killgerät CWFL-15000KNPTY-UL ass fir 12kW-15kW Faserlasersystemer entwéckelt, déi beim schwéiere Schneiden, Schweessen a Metallveraarbechtung agesat ginn. Mat enger Killkapazitéit vu 37kW mat duebelen onofhängege Killkreesser bitt en eng stabil Wärmeverwaltung fir usprochsvoll industriell Uwendungen. Onofhängeg vun SGS no UL- a CSA-Standarden getest, ass en gebaut fir den nordamerikaneschen elektresche Sécherheetsufuerderungen ze erfëllen.


Mat intelligenter Duebeltemperaturkontroll, RS-485 Modbus RTU Kommunikatioun a Multi-Level-Schutz ënnerstëtzt den TEYU CWFL-15000KNPTY-UL e verlässleche Betrib ënner héije Produktiounslaaschten. En ass ideal fir d'Veraarbechtung vu Stolstrukturen, d'Schneiden vun Déckplacken an aner Uwendungen an der schwéierer industrieller Produktioun.

Product characteristics

Product Parameters

ModellCWFL-15000KNPTY-UL SpannungAC 3P 460V~480V
Frequenz 60Hz Aktuell3.7~28.4A
Maximalen Energieverbrauch 18,1 kW Heizungsleistung600W+3600W
Nominal Killkapazitéit 126249 Btu/h KältemëttelR-32
37 kW Präzisioun ±1℃
31814 kcal/h Reduzéierer Kapillär
Pompelkraaft 3kW Tankkapazitéit170L
Entrée an Auslaaf Rp1/2"+Rp1-1/4" Max. Pompeldrock 6 Bar
Bewäertungsduerchfluss 2,5 l/min + >133 l/min Dimensioun 145 × 80 × 132 cm (L × B × H)
N.W. 290 kg Package Dimensioun 147 × 92 × 150 cm (L × B × H)
G.W. 333 kg

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop available to instantly eliminate hazards
Emergency Stop available to instantly eliminate hazards
Multiple warning protections: water level alarm, over-temperature alarm, water flow alarm...
Thermal insulation for water tubing, pump and evaporator.
Fully hermetic compressor with built-in motor protection.
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Stainless steel filter
Recyclable and anti-clogging
Water pressure gauge
Display of water pump status and water pressure
Waterproof junction box
Safe and stable, flexible power cable installation
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Heem   |     Produkter       |     SGS & UL Killmaschinn       |     Killléisung     |     Firma      |    Ressource       |      Nohaltegkeet
Copyright © 2026 TEYU S&A Killmaschinn | Sitemap Dateschutzbestimmungen
Kontaktéiert eis
email
Kontaktéiert Clientsservice
Kontaktéiert eis
email
Ofbriechen
Customer service
detect