loading
Chiyankhulo

SGS-Yoyesedwa CHIKWANGWANI Laser Chiller CWFL-15000KNPTY-UL

Chiller cha Industrial Chogwirizana ndi UL & CSA cha 12kW-15kW Chodulira ndi Kupanga Fiber Laser

TEYU CWFL-15000KNPTY-UL industrial chiller idapangidwa kuti igwiritse ntchito makina a laser a 12kW-15kW omwe amagwiritsidwa ntchito podula, kuwotcherera, komanso kupanga zitsulo. Pokhala ndi mphamvu yoziziritsira ya 37kW yokhala ndi ma circuits awiri odziyimira pawokha, imapereka kasamalidwe kokhazikika ka kutentha kwa mafakitale kuti igwiritsidwe ntchito molimbika. Yoyesedwa payokha ndi SGS ku miyezo ya UL & CSA, yapangidwa kuti ikwaniritse zofunikira zachitetezo chamagetsi ku North America.


Ili ndi mphamvu yowongolera kutentha kwawiri, kulumikizana kwa RS-485 Modbus RTU, komanso chitetezo cha magawo ambiri, TEYU CWFL-15000KNPTY-UL imathandizira kugwira ntchito kodalirika pansi pa ntchito zambiri zopangira. Ndi yabwino kwambiri pokonza zitsulo, kudula mbale zokhuthala, ndi ntchito zina zolemera zopangira mafakitale.

Product characteristics

Product Parameters

ChitsanzoCWFL-15000KNPTY-UL VotejiAC 3P 460V~480V
Kuchuluka kwa nthawi 60Hz Zamakono3.7~28.4A
Kugwiritsa ntchito mphamvu kwambiri 18.1kW Mphamvu ya chotenthetsera600W+3600W
Mphamvu yozizira yodziwika 126249Btu/h FirijiR-32
37kW Kulondola ±1℃
31814Kcal/h Wochepetsa Kapilari
Mphamvu ya pampu 3kW Kuchuluka kwa thanki170L
Malo olowera ndi otulutsira Rp1/2"+Rp1-1/4" Kupanikizika kwakukulu kwa pampu Malo okwana 6
Kuyenda koyesedwa 2.5L/mphindi + >133Lmphindi Kukula 145 × 80 × 132cm(L × W × H)
N.W. 290kg Mulingo wa phukusi 147 × 92 × 150cm(L × W × H)
G.W. 333kg

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop available to instantly eliminate hazards
Emergency Stop available to instantly eliminate hazards
Multiple warning protections: water level alarm, over-temperature alarm, water flow alarm...
Thermal insulation for water tubing, pump and evaporator.
Fully hermetic compressor with built-in motor protection.
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Stainless steel filter
Recyclable and anti-clogging
Water pressure gauge
Display of water pump status and water pressure
Waterproof junction box
Safe and stable, flexible power cable installation
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Kunyumba   | |     Zogulitsa       | |     SGS & UL Chiller       | |     Njira Yozizira     | |     Kampani      |    Zothandizira       | |      Kukhazikika
Copyright © 2026 TEYU S&A Chiller | Mapu a Tsamba Ndondomeko yachinsinsi
Lumikizanani nafe
email
Kulumikizana ndi Makasitomala
Lumikizanani nafe
email
siya
Customer service
detect