loading
Puo

SGS-Lekoa fiber Laser Chiller CWFL-15000KNPTY-UL

Chiller ea Liindasteri e Latelang UL & CSA bakeng sa ho Seha le ho Etsa ka Laser ea Faeba ea 12kW-15kW

TEYU CWFL-15000KNPTY-UL industrial chiller e entswe bakeng sa ditsamaiso tsa laser ya faeba ya 12kW-15kW tse sebediswang ho seheng ka thata, ho tjheseletsa le ho etsa tshepe. E fana ka bokgoni ba ho phodisa ba 37kW ka dipotoloho tse pedi tse ikemetseng tsa ho phodisa, e fana ka taolo e tsitsitseng ya mocheso bakeng sa ditshebediso tse hlokang tsa indasteri. E lekotswe ka boikemelo ke SGS ho ya ho maemo a UL le CSA, e hahilwe ho fihlela ditlhoko tsa polokeho ya motlakase tsa Amerika Leboya.


E na le taolo e bohlale ea mocheso o habeli, puisano ea RS-485 Modbus RTU, le tšireletso ea maemo a mangata, TEYU CWFL-15000KNPTY-UL e tšehetsa ts'ebetso e tšepahalang tlas'a mesebetsi e mengata ea tlhahiso. E loketse ts'ebetso ea tšepe ea meaho, ho seha lipoleiti tse teteaneng, le lits'ebetso tse ling tse boima tsa tlhahiso ea indasteri.

Product characteristics

Product Parameters

MohlalaCWFL-15000KNPTY-UL Palo ea li-voltsAC 3P 460V~480V
Maqhubu 60Hz Hona joale3.7~28.4A
Tšebeliso e phahameng ka ho fetisisa ea matla 18.1kW Matla a hitara600W+3600W
Bokhoni ba ho pholisa bo ikgethang 126249Btu/h SehatsetsingR-32
37kW Ho nepahala ±1℃
31814Kcal/h Sefokotsi Mothapo oa mali
Matla a pompo 3kW Bokhoni ba tanka170L
Monyako le sehokelo Rp1/2"+Rp1-1/4” Khatello e phahameng ea pompo Bara e 6
Phallo e lekantsoe 2.5L/motsotso+ >133Lmin Tekanyo 145 × 80 × 132cm(L × W × H)
N.W. 290kg Tekanyo ea sephutheloana 147 × 92 × 150cm(L × W × H)
G.W. 333kg

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop available to instantly eliminate hazards
Emergency Stop available to instantly eliminate hazards
Multiple warning protections: water level alarm, over-temperature alarm, water flow alarm...
Thermal insulation for water tubing, pump and evaporator.
Fully hermetic compressor with built-in motor protection.
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Stainless steel filter
Recyclable and anti-clogging
Water pressure gauge
Display of water pump status and water pressure
Waterproof junction box
Safe and stable, flexible power cable installation
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Lehae   |     Lihlahisoa       |     SGS & UL Chiller       |     Tharollo ea ho Pholisa     |     Khampani      |    Mohlodi       |      Moshoelella
Tokelo ea Mongoli © 2026 TEYU S&A Chiller | 'Mapa oa Sebaka Leano la Lekunutu
Iteanye le rona
email
Ikopanye le ts'ebeletso ea bareki
Iteanye le rona
email
hlakola
Customer service
detect