TEYU CWFL-15000KNPTY-UL industrial chiller yakagadzirwa kuti ishande ne12kW-15kW fiber laser systems inoshandiswa mukucheka, kusanganisa, uye kugadzira simbi. Iine simba rekutonhodza re37kW rine macircuit maviri akazvimiririra ekutonhodza, inopa manejimendi yekupisa yakasimba kumashandisirwo emaindasitiri. Yakaedzwa yega neSGS kune UL & CSA standards, yakavakwa kuti ienderane nezvinodiwa zvekuchengetedza magetsi kuNorth America.


Iine hungwaru hwekudzora tembiricha mbiri, RS-485 Modbus RTU kutaurirana, uye dziviriro yematanho akawanda, TEYU CWFL-15000KNPTY-UL inotsigira mashandiro akavimbika pasi pemabasa akawanda ekugadzira. Yakanakira kugadzirisa simbi yekuvaka, kucheka maplate akakora, uye mamwe mashandisirwo ekugadzira maindasitiri anorema.

Product characteristics

Product Parameters

MuenzanisoCWFL-15000KNPTY-UL VoltageAC 3P 460V~480V
Kakawanda 60Hz Zvazvino3.7~28.4A
Kushandiswa kwesimba zvakanyanya 18.1kW Simba rehita600W+3600W
Kukwanisa kutonhora kwemazita 126249Btu/h RefrigerantR-32
37kW Kunyatsojeka ±1℃
31814Kcal/h Mudzikisi Mutsinga weropa
Simba repombi 3kW Kukwanisa kwetangi170L
Musuwo wekupinda nepakubuda Rp1/2"+Rp1-1/4" Kumanikidzwa kukuru kwepombi 6 bhawa
Kuyerera kwakayerwa 2.5L/min+ >133Lmin Chiyero 145 × 80 × 132cm(L × W × H)
N.W. 290kg Chiyero chepakeji 147 × 92 × 150cm(L × W × H)
G.W. 333kg

Product Features

Precise Temperature Control
Delivers stable and accurate cooling performance to prevent overheating and ensure consistent processing quality.
Efficient Cooling System
Uses advanced compressors and heat exchangers for fast heat dissipation under high-load conditions.
Real-Time Monitoring & Alarms
Features a smart display with real-time monitoring and fault alarms to ensure safe operation.
Energy Efficient Design
Incorporates energy-saving components to minimize power usage while maintaining strong cooling efficiency.
Compact & Easy Operation
Compact design fits tight spaces, with intuitive controls for quick setup and simple daily use.
Certified for Global Standards
Complies with international safety and quality certifications for reliable use across global industries.
Durable & Highly Reliable
Constructed with robust materials and safety alarms for continuous, long-term, and stable performance.
Comprehensive 2-Year Warranty
Comes with a full 2-year warranty to guarantee long-term reliability and user confidence.

Details

Emergency Stop available to instantly eliminate hazards
Emergency Stop available to instantly eliminate hazards
Multiple warning protections: water level alarm, over-temperature alarm, water flow alarm...
Thermal insulation for water tubing, pump and evaporator.
Fully hermetic compressor with built-in motor protection.
Temperature controller
Display water temperature
of laser & optics cooling circuits Temperature stability of ±1℃
Stainless steel filter
Recyclable and anti-clogging
Water pressure gauge
Display of water pump status and water pressure
Waterproof junction box
Safe and stable, flexible power cable installation
Premium axial fan
Quiet, efficient heat dissipation and maintenance-free
Double-effect heating
Plate heat exchanger and heater to achieve efficient heating to prevent condensation.

Certificate

Working principle

Ventilation Distance

FAQ

1
Is TEYU Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
2
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
3
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
4
What is the ideal room temperature for the water chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
5
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Kumba   |     Products       |     SGS & UL Chiller       |     Kutonhora Solution     |     Company      |    Resource       |      Sustainability
Kodzero Dzepamutemo © 2026 TEYU S&A Chiller | Mepu yeSaiti Mutemo wekuchengetedza ruzivo
Taura nesu
email
Bata Vatengi Service
Taura nesu
email
kanzura
Customer service
detect