How to deal with E1 alarm of laser cooling chiller which cools chip UV laser marking machine?

How to deal with E1 alarm of laser cooling chiller which cools chip UV laser marking machine?

laser cooling

E1 alarm stands for ultrahigh room temperature alarm. If E1 alarm occurs to laser cooling chiller which cools chip UV laser marking machine, the error code and the water temperature will be displayed alternatively with beeping. In this case, pressing any key can stop the beeping, but the error code can not be eliminated until the problem is solved. To eliminate the E1 error code, please put the laser cooling chiller under the environment of below 40 degree celsius and with good ventilation. 

In respect of production, S&A Teyu has invested the production equipment of more than one million yuan, ensuring the quality of a series of processes from the core components (condenser) of industrial chiller to the welding of sheet metal; in respect of logistics, S&A Teyu has set up logistics warehouses in the main cities of China, having greatly reduced the damage due to the long-distance logistics of the goods, and improved transport efficiency; in respect of after-sales service, the warranty period is two years.

laser cooling chiller

prev
What is the product range for JPT Laser?
Is it appropriate to use S&A water chiller unit CW-5300 to cool 60W-80W sealed CO2 laser tube?
next

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
Contact us
email
Contact customer service
Contact us
email
cancel
Customer service
detect