loading

How to deal with the water flow alarm of recirculating closed loop water chiller which cools 3D UV laser marking machine?

How to deal with the water flow alarm of recirculating closed loop water chiller which cools 3D UV laser marking machine?

laser cooling

When the recirculating closed loop water chiller which cools 3D UV laser marking machine triggers water flow alarm, there will be beeping and it needs to be dealt with in time. Water flow alarm can be caused by the following problems and users can locate the real problem by detecting them one by one. 

1.The external circulation waterway of the recirculating closed water chiller is blocked. In this case, please remove the blocking.

2.The internal circulation waterway of the recirculating closed loop water chiller is blocked. In this case, use clean water to flush the waterway and then use the air gun to blow it. 

3.The water pump has impurities. In this case, clean the water pump.

4.The water pump rotor wears out which makes the water pump age seriously. In this case, please replace the whole water pump.

In respect of production, S&A Teyu has invested the production equipment of more than one million yuan, ensuring the quality of a series of processes from the core components (condenser) of industrial chiller to the welding of sheet metal; in respect of logistics, S&A Teyu has set up logistics warehouses in the main cities of China, having greatly reduced the damage due to the long-distance logistics of the goods, and improved transport efficiency; in respect of after-sales service, the warranty period is two years.

recirculating closed loop water chiller

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
Contact us
email
Contact customer service
Contact us
email
cancel
Customer service
detect