Ultrafast Laser & UV Laser Chiller
VR
Product Introduction
Compact Recirculating Chiller CWUL-05 for UV Laser Marking Machine

Model: CWUL-05

Machine Size: 58 X 29 X 52cm (L X W X H)

Warranty: 2 years

Standard: CE, REACH and RoHS

Product Parameters
ModelCWUL-05
VoltageAC 1P 220-240V
Frequency50Hz
Current0.5-3.1A

Max. power consumption

0.77 kW


Compressor power

0.19 kW
0.25HP



Nominal cooling capacity

1467 Btu/h
0.43 kW
369 Kcal/h
RefrigerantR-134a
Precision±0.2℃
ReducerCapillary
Pump power0.05kW
Tank capacity6L
Inlet and outletRp1/2”

Max. pump pressure

12M
Max. pump flow13L/min
N.W21Kg
G.W24Kg
Dimension58 X 29 X 52cm (L X W X H)
Package dimension65 X 36 X 56cm (L X W X H)

The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

Product Features

* Cooling Capacity: 430W

* Active cooling

* Temperature stability: ±0.2°C

* Temperature control range: 5°C ~35°C

* Refrigerant: R-134a

* Compact and lightweight package

* Easy water fill port                                          

* Visual water level

* Integrated alarm functions

* Easy maintenance and mobility

Optional Items

              

 Heater


               

Filter


              

 US standard plug / EN standard plug


Product Details
Compact Recirculating Chiller CWUL-05 Intelligent temperature controller
                                       

Intelligent temperature controller


The temperature controller offers high precision temperature control of ±0.2°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode.

Compact Recirculating Chiller CWUL-05 Easy-to-read water level indicator
                                       

Easy-to-read water level indicator


The water level indicator has 3 color areas - yellow, green and red.

Yellow area - high water level.

Green area - normal water level.

Red area - low water level.  

Compact Recirculating Chiller CWUL-05 Integrated top mounted handles
                                       

Integrated top mounted handles


The firm handles are mounted on top for easy mobility.

Ventilation Distance

Compact Recirculating Chiller CWUL-05 Ventilation Distance

Certificate
Compact Recirculating Chiller CWUL-05 Certificate
Product Working Principle

Compact Recirculating Chiller CWUL-05 Product Working Principle

FAQ
Is S&A Chiller a trading company or a manufacturer?
We are professional industrial chiller manufacturer since 2002.
What is the recommended water used in the industrial water chiller?
The ideal water should be deionised water, distilled water or purified water.
How often should I change out the water?
Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
What is the ideal room temperature for the chiller?
The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
How to prevent my chiller from freezing?
For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team ([email protected]) first.
Basic Information
  • Year Established
    --
  • Business Type
    --
  • Country / Region
    --
  • Main Industry
    --
  • Main Products
    --
  • Enterprise Legal Person
    --
  • Total Employees
    --
  • Annual Output Value
    --
  • Export Market
    --
  • Cooperated Customers
    --

If You Have More Questions, Write To Us

Just leave your email or phone number on the contact form so we can provide you with more services!

Send your inquiry

Choose a different language
English English العربية العربية Deutsch Deutsch Español Español français français italiano italiano 日本語 日本語 한국어 한국어 Português Português русский русский 简体中文 简体中文 繁體中文 繁體中文 Afrikaans Afrikaans አማርኛ አማርኛ Azərbaycan Azərbaycan Беларуская Беларуская български български বাংলা বাংলা Bosanski Bosanski Català Català Sugbuanon Sugbuanon Corsu Corsu čeština čeština Cymraeg Cymraeg dansk dansk Ελληνικά Ελληνικά Esperanto Esperanto Eesti Eesti Euskara Euskara فارسی فارسی Suomi Suomi Frysk Frysk Gaeilgenah Gaeilgenah Gàidhlig Gàidhlig Galego Galego ગુજરાતી ગુજરાતી Hausa Hausa Ōlelo Hawaiʻi Ōlelo Hawaiʻi हिन्दी हिन्दी Hmong Hmong Hrvatski Hrvatski Kreyòl ayisyen Kreyòl ayisyen Magyar Magyar հայերեն հայերեն bahasa Indonesia bahasa Indonesia Igbo Igbo Íslenska Íslenska עִברִית עִברִית Basa Jawa Basa Jawa ქართველი ქართველი Қазақ Тілі Қазақ Тілі ខ្មែរ ខ្មែរ ಕನ್ನಡ ಕನ್ನಡ Kurdî (Kurmancî) Kurdî (Kurmancî) Кыргызча Кыргызча Latin Latin Lëtzebuergesch Lëtzebuergesch ລາວ ລາວ lietuvių lietuvių latviešu valoda‎ latviešu valoda‎ Malagasy Malagasy Maori Maori Македонски Македонски മലയാളം മലയാളം Монгол Монгол मराठी मराठी Bahasa Melayu Bahasa Melayu Maltese Maltese ဗမာ ဗမာ नेपाली नेपाली Nederlands Nederlands norsk norsk Chicheŵa Chicheŵa ਪੰਜਾਬੀ ਪੰਜਾਬੀ Polski Polski پښتو پښتو Română Română سنڌي سنڌي සිංහල සිංහල Slovenčina Slovenčina Slovenščina Slovenščina Faasamoa Faasamoa Shona Shona Af Soomaali Af Soomaali Shqip Shqip Српски Српски Sesotho Sesotho Sundanese Sundanese svenska svenska Kiswahili Kiswahili தமிழ் தமிழ் తెలుగు తెలుగు Точики Точики ภาษาไทย ภาษาไทย Pilipino Pilipino Türkçe Türkçe Українська Українська اردو اردو O'zbek O'zbek Tiếng Việt Tiếng Việt Xhosa Xhosa יידיש יידיש èdè Yorùbá èdè Yorùbá Zulu Zulu
Current language:English
Send Your Inquiry