TEYU water chiller cooling system CW-6000 developed by TEYU chiller manufacturer is programmed to perform high quality refrigeration for a wide variety of industrial, medical, analytical and laboratory applications. Proven 24/7 reliability, extremely high energy efficiency and durability set us apart in the refrigeration industry. 

Industrial process water chiller CW 6000 offers 3140W cooling capacity while maintaining the temperature fluctuation at ±0.5°C. CW-6000 chiller incorporates a high quality compressor for optimum performance and less energy consumption. A user-friendly control panel allows you to set your desired temperature as needed or leave the water temperature automatically adjusting itself in the range of 5°C to 35°C. 

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    Industrial Chiller System CW-6000 3140W Cooling Capacity

    Model: CW-6000

    Machine Size: 59X38X74cm (L X W X H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    Model CW-6000AHTY CW-6000BHTY CW-6000DHTY CW-6000AITY CW-6000BITY CW-6000DITY CW-6000ANTY CW-6000BNTY CW-6000DNTY
    Voltage AC 1P 220-240V AC 1P 220-240V AC 1P 110V AC 1P 220-240V AC 1P 220-240V AC 1P 110V AC 1P 220-240V AC 1P 220-240V AC 1P 110V
    Frequency 50Hz 60Hz 60Hz 50Hz 60Hz 60Hz 50Hz 60Hz 60Hz
    Current 0.5~5.2A 0.5~4.9A 0.5~8.9A 0.4~5.1A 0.4~4.8A 0.4~8.8A 2.3~7A 2.1~6.6A 6~14.4A

    Max. power consumption

    1.08kW 1.04kW 0.96kW 1.12kW 1.08kW 1kW 1.4kW 1.36kW 1.51kW

    Compressor power

    0.94kW 0.88kW 0.79kW 0.94kW 0.88kW 0.79kW 0.94kW 0.88kW 0.79kW
    1.26HP 1.17HP 1.06HP 1.26HP 1.17HP 1.06HP 1.26HP 1.17HP 1.06HP

    Nominal cooling capacity

    10713Btu/h
    3.14kW
    2699Kcal/h
    Pump power 0.05kW 0.09kW 0.37kW 0.6kW

    Max. pump pressure

    1.2bar 2.5bar 2.7bar 4bar

    Max. pump flow

    13L/min 15L/min 75L/min
    Refrigerant R-410A
    Precision ±0.5℃
    Reducer Capillary
    Tank capacity 12L
    Inlet and outlet Rp1/2"
    N.W. 35Kg 36Kg 43Kg
    G.W. 44Kg 45Kg 52Kg
    Dimension 59X38X74cm (L X W X H)
    Package dimension 66X48X92cm (L X W X H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    * Cooling Capacity: 3140W

    * Active cooling

    * Temperature stability: ±0.5°C

    * Temperature control range: 5°C ~35°C

    * Refrigerant: R-410A

    * User-friendly temperature controller

    * Integrated alarm functions

    * Back mounted water fill port and easy-to-read water level check

    * Multiple power specifications

    * High reliability, energy efficiency and durability

    * Simple setup and operation

    Application

    * Laboratory equipment (rotary evaporator, vacuum system)

    * Analytical equipment (spectrometer, bio analyzes, water sampler)

    * Medical diagnostic equipment(MRI, X-ray)

    * Machine tool (high speed spindle)

    * Plastic molding machines

    * Printing machine

    * Furnace

    * Welding machine

    * Packaging machinery

    * Plasma etching machine

    * UV curing machine

    * Gas generators

    * Helium compressor (cryo compressors)

    Optional Items

                  

     Heater

     

                   

    Filter

     

                  

     US standard plug / EN standard plug

     

    Product Details
    Industrial Chiller System CW-6000 Intelligent temperature controller
                                           

    Intelligent temperature controller

     

    The temperature controller offers high precision temperature control of ±0.5°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode.

    Industrial Chiller System CW-6000 Easy-to-read water level indicator
                                           

    Easy-to-read water level indicator

     

    The water level indicator has 3 color areas - yellow, green and red.

    Yellow area - high water level.

    Green area - normal water level.

    Red area - low water level.  

    Industrial Chiller System CW-6000 Caster wheels for easy mobility
                                           

    Caster wheels for easy mobility

     

    Four caster wheels offer easy mobility and unmatched flexibility.

    Ventilation Distance

    Industrial Chiller System CW-6000 Ventilation Distance

    Certificate
    Industrial Chiller System CW-6000 Certificate
    Product Working Principle

    Industrial Chiller System CW-6000 Product Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the water chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect