loading
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 1
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 2
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 3
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 4
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 5
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 6
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 7
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 1
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 2
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 3
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 4
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 5
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 6
Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 7

Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine

Rack mount recirculating laser chiller RMFL-2000 is developed by S&A Teyu based on the laser welding market demand and is applicable to cool 2KW handheld fiber laser welding machine. Rack mount water chiller RMFL-2000 features ±0.5℃ temperature stability with dual temperature control system which is capable of cooling the fiber laser and the laser head at the same time. In addition, it is designed with intelligent & constant temperature modes which can meet different demands in different situations.

  • Item NO.:

    RMFL-2000

  • Product Origin:

    Guangzhou,China

  • Shipping Port:

    Guangzhou,China

  • Cooling capacity:

    5.18KW

  • Precision:

    ±0.5℃

  • Voltage:

    220V

  • Frequency:

    50Hz

  • Refrigerant:

    R-410a

  • Reducer:

    capillary

  • Pump power:

    0.55KW

  • Tank capacity:

    18L

  • Inlet and outlet:

    Rp1/2+Rp1/2

  • N.W:

    79Kgs

  • G.W:

    89Kgs

  • Dimension:

    88*48*45(L*W*H)

  • Package dimension:

    97*56*65(L*W*H)

    oops...!

    no product data.

    Go to homepage

    Product Description

    fiber laser chiller

    Rack mount recirculating laser chiller RMFL-2000 is developed by S&A Teyu based on the laser welding market demand and is applicable to cool 2KW handheld fiber laser welding machine. Rack mount fiber laser chiller RMFL-2000 features ±0.5℃ temperature stability with dual temperature control system which is capable of cooling the fiber laser and the laser head at the same time. In addition, it is designed with intelligent & constant temperature modes which can meet different demands in different situations. 



      Features  
    1. With environmental refrigerant;
    2. ±0.5℃ precise temperature control;
    3. The intelligent temperature controller has 2 control modes applicable in different occasions; with various setting and display functions;
    4. Dual temperature control system to satisfy different needs of fiber laser device and laser head;
    5. Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
    6. CE approval; RoHS approval; REACH approval;
    7. Optional heater and water filter.

    THE WARRANTY IS 2 YEARS AND THE PRODUCT IS UNDERWRITTEN BY INSURANCE COMPANY.


      Specification  

    parameter

    Note: the working current can be different under different working conditions; The above information is for reference only. Please subject to the actual delivered product.


      PRODUCT INTRODUCTION  


    Independent production of sheet metal, evaporator and condenser

    - Adopt IPG fiber laser for welding and cutting sheet metal. 



    High precision temperature control system with dual temperature control function

    - Temperature control accuracy can reach ±0.5℃. High temp. for laser head and low temp. for laser device.


    Multiple alarm protection

    - The laser will stop working once it receives alarm signal from the water chiller for protection purpose.


    temperature controller


    Equipped with drain outlet.

    drain outlet


    Dual inlet and dual outlet connector equipped. Cooling fan of famous brand installed.

    - Water Chiller inlet connects to laser outlet connector. Chiller outlet connects to laser inlet connector.

    water inlet & outlet and cooling fan


    Level gauge equipped

    level gauge



     

      TEMPERATURE CONTROLLER PANEL DESCRIPTION  

    S&A Teyu industrial water chillers are popular for its 2 temperature control modes as constant and intelligent temperature control.Generally speaking, the defaulted setting for the temperature controller is intelligent temperature control mode. Under intelligent temperature control mode, the water temperature will adjust itself according to the ambient temperature. However, under constant temperature control mode, users can adjust the water temperature manually.


    water chiller temp controller

    Temperature controller panel description:

    Rack mount recirculating laser chiller RMFL-2000 for 2KW handheld fiber laser welding machine 15


      Alarm function  

    (1)  Alarm Display:
    500W fiber laser chiller alarm display
    When alarm occurs, the error code and the temperature will be alternately displayed.
    (2) To suspend the alarm:
    In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display remains until the alarm condition is eliminated.



      ALARM AND OUTPUT PORTS  

    In order to guarantee the equipment will not be affected while abnormal situation happens to the chiller, RMFL-1000 chiller is designed with alarm protection function.
    1. Alarm output terminals and wiring diagram.
    cwfl500 chillers ALARM AND OUTPUT PORTS
    2. Alarm causes and working status table.
    water chillers Alarm causes and working status

    Note: The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.



      CHILLER APPLICATION 

    water CHILLER APPLICATION




      WAREHOUSE  
    18,000 square meters brand new industrial refrigeration system research center and production base. Strictly execute ISO production management system, using mass modularized standard production. Standard parts rate up to 80%, which are the source of stable quality. 

    air cooled water chillers workshop



      TEST SYSTEM  

    With excellent laboratory testing system which simulates actual working environment of the chiller. Overall performance testing before delivery: aging test and complete performance test must be performed on each finished chiller.

    WATER CHILLER TEST SYSTEM



    Video

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect