Low-GWP chillers are gaining attention as manufacturers in laser processing, medical equipment, precision manufacturing, and other industries look for cooling solutions that align with evolving environmental regulations.
A low-GWP chiller is an industrial cooling system that uses a refrigerant with a relatively low Global Warming Potential (GWP). However, choosing one involves more than comparing refrigerant values. System design, safety classification, cooling requirements, and regional regulations all need to be considered.
This guide explains what low-GWP means, why it matters, how common low-GWP refrigerants compare, and what industrial buyers should know when selecting a chiller.
1. What Does "Low-GWP" Mean?
GWP (Global Warming Potential) measures how much heat a greenhouse gas traps in the atmosphere over a specific period, typically 100 years, compared with carbon dioxide (CO2), which has a GWP of 1.
A higher GWP indicates a greater potential contribution to global warming if the refrigerant is released into the atmosphere.
Common refrigerants used in industrial chillers have different GWP values:
* R-410A, approximate GWP (100-year) ≈2,088
* R-134a, approximate GWP (100-year) ≈1430
* R-32, approximate GWP (100-year) ≈675
* R-513A, approximate GWP (100-year) ≈631
* R-1234yf, approximate GWP (100-year) ≈0.501
Values are based on applicable regulatory reference data. GWP figures may vary slightly depending on the IPCC assessment basis.
Compared with traditional refrigerants such as R-134a and R-410A, alternatives such as R-32, R-513A, and R-1234yf have lower GWP values. Ranging from approximately 675 down to 0.501, these alternatives help reduce the direct climate impact of refrigerant leakage and support compliance in regulated markets.
2. Why Are Low-GWP Chillers Gaining Adoption?
The shift toward low-GWP refrigerant chillers is largely driven by international climate policies, particularly the EU F-gas Regulation and the US AIM Act. These regulations introduce restrictions on the use of refrigerants with higher GWP values in certain types of new equipment.
EU F-gas Regulation (EU) 2024/573
The EU is phasing down the use of fluorinated greenhouse gases (F-gases) through equipment-specific restrictions:
| Timeline | Equipment | GWP Restriction |
|---|---|---|
| From Jan 1, 2027 | Stationary chillers with rated cooling capacity ≤ 12 kW | GWP < 150 |
| From Jan 1, 2027 | Stationary chillers with rated cooling capacity > 12 kW | GWP < 750 |
| From Jan 1, 2032 | Stationary chillers with rated cooling capacity ≤ 12 kW | Fluorinated greenhouse gases prohibited, subject to safety exceptions |
US AIM Act and EPA Technology Transitions Program
In the United States, the EPA has introduced GWP limits for specific equipment categories under the AIM Act. For chillers, restrictions depend on the application and the temperature of the fluid exiting the chiller:
| Compliance Date | Equipment | GWP Limit |
|---|---|---|
| From Jan 1, 2026 | Industrial process chillers with exiting fluid temperature ≥ -30°C | < 700 |
| From Jan 1, 2028 | Industrial process chillers with exiting fluid temperature ≥ -50°C and < -30°C | < 700 |
| From Jan 1, 2030 | Certain semiconductor manufacturing chillers with refrigerant charge ≤100 lb | < 700 |
Not all low-GWP refrigerants have the same properties. Their GWP values, safety classifications, and operating characteristics influence which cooling systems they are suitable for.
| Refrigerant | GWP | Safety Class | Key Characteristics |
|---|---|---|---|
| R-1234yf | 0.501 | A2L | Very low GWP; suitable for selected systems prioritizing reduced refrigerant climate impact. |
| R-32 | 675 | A2L | GWP below 700; used in selected systems designed for its operating and safety requirements. |
| R-513A | 631 | A1 | Non-flammable, lower-GWP alternative to R-134a. |
Understanding Refrigerant Safety Classifications
Refrigerant safety classifications help identify toxicity and flammability characteristics:
* A1: Lower toxicity and no flame propagation under classification test conditions.
* A2L: Lower toxicity and lower flammability, with limited flame propagation and lower burning velocity.
The choice between A1 and A2L refrigerants depends on the chiller's design, refrigerant charge, installation environment, and applicable safety standards. A lower GWP value alone does not determine whether a refrigerant is suitable for a particular application.
4. FAQ: Common Questions About Low-GWP Chillers
1) Can low-GWP chillers provide the same cooling performance as traditional chillers?
Yes, when properly engineered. Low-GWP refrigerants are not necessarily drop-in replacements for existing systems, so compatibility and design adjustments must be considered. With compressors, expansion valves, and heat exchangers matched to the refrigerant's properties, a properly designed chiller can deliver reliable cooling capacity and temperature stability in line with its rated specifications. Actual performance depends on the model and operating conditions.
2) Are low-GWP refrigerants safe for industrial use?
Yes, when designed, installed, and operated according to applicable safety standards. For example, R-513A is classified as A1 (non-flammable), while R-32 and R-1234yf are classified as A2L (lower flammability). Buyers should always verify the refrigerant type, safety classification, equipment certification, and installation ventilation requirements before selecting a chiller.
3) Do existing industrial chillers need to be replaced because of new regulations?
Not necessarily. Most refrigerant restrictions focus on new equipment placed on the market or imported after specified compliance dates. Existing R-134a or R-410A chillers are not automatically subject to replacement requirements, though future refrigerant availability and servicing rules remain subject to local regulations. Considering refrigerant options during new equipment selection helps support long-term compliance planning.
5. Explore TEYU Low-GWP Chiller Solutions
TEYU S&A offers a wide range of industrial chillers with flexible refrigerant configurations to serve diverse global markets.
Alongside established refrigerants such as R-410A and R-134a for regions where low-GWP alternatives are not required and their use is permitted, TEYU provides mature low-GWP chiller solutions using R-1234yf, R-32, and R-513A in selected models, with ongoing product rollouts tailored for European and North American standards.
As global regulations and industry needs continue to evolve, TEYU actively invests in refrigeration R&D, advancing chiller engineering and developing next-generation cooling solutions adapted to emerging refrigerants, stricter safety codes, and diverse regional requirements.
From laser processing and CNC machining to electronics, medical equipment, and laboratories, TEYU delivers reliable temperature control solutions for a wide range of industrial applications. Explore TEYU Industrial Chillers or contact our engineering team via sales@teyuchiller.com to configure the right chiller for your equipment and target market.