loading

What is the reason that laser chiller unit which cools fabric laser cutting machine fails to refrigerate?

What is the reason that laser chiller unit which cools fabric laser cutting machine fails to refrigerate?

laser cooling

According to the experience of S&A Teyu, the possible reason that laser chiller unit which cools fabric laser cutting machine fails to refrigerate is listed below:

1.Something is wrong with the temperature controller of the laser chiller unit;

2.The cooling capacity of the laser chiller unit can’t meet the cooling requirement of the device;

 If that problem occurs after the laser chiller unit is used for a certain period of time, then it probably is due to :

1.The heat exchanger of the laser chiller unit is too dirty and it needs to be cleaned;

2.The laser chiller unit is leaking refrigerant. It is suggested to find and weld the leakage point and refill the refrigerant;

3.The working environment of laser chiller unit is either too cold or too hot, which makes the chiller can’t fulfill the requirement of the device. It is suggested to select a larger chiller model.

In respect of production, S&A Teyu has invested the production equipment of more than one million yuan, ensuring the quality of a series of processes from the core components (condenser) of industrial chiller to the welding of sheet metal; in respect of logistics, S&A Teyu has set up logistics warehouses in the main cities of China, having greatly reduced the damage due to the long-distance logistics of the goods, and improved transport efficiency; in respect of after-sales service, the warranty period is two years.

laser chiller unit

We're here for you when you need us.

Please complete the form to contact us, and we'll be happy to help you.

Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
Contact us
email
Contact customer service
Contact us
email
cancel
Customer service
detect