What makes the cooling fan of the industrial water chiller which cools fabric laser cutting machine fail to work?

laser cooling chiller

The cooling fan of the industrial water chiller which cools fabric laser cutting machine fails to work all of a sudden? What could be the reason? 

According to the experience of S&A Teyu, the following reasons could lead to the non-working of the cooling fan.

1.The circuit of the cooling fan is in poor contact or loose. In this case, please check and adjust the circuit accordingly.

2.The capacitance is decreasing. Please replace with a new capacitance. 

3.The coil of the cooling fan is burnt out. It is suggested to change the whole cooling fan. 

After 17-year development, we establish rigorous product quality system and provide well-established after-sales service. We offer more than 90 standard water chiller models and 120 water chiller models for customization. With cooling capacity ranging from 0.6KW to 30KW, our water chillers are applicable to cool different laser sources,laser processing machines, CNC machines, medical instruments, laboratory equipment and so on. 