Water pump plays an important role in the smooth water circulation inside industrial water cooling chiller unit which cools CCD laser cutting machine. If it is broken, what should be done? Well, first of all, we should locate the cause first. Below are the possible causes:
1.The supplied voltage is not stable;
2.The industrial water cooling chiller unit has water leakage problem, but users haven’t noticed. When the water is completely out, the water pump starts to dry running, leading to the breaking of the water pump;
3.The voltage or the frequency is not matched.
For the related solutions, we list them below:
1.Add a voltage stabilizer;
2.Find out the leakage point and replace the pipe if necessary;
3.Before purchasing the industrial water cooling chiller unit, please notice that if the local voltage & frequency matches the ones of the chiller or not.
After 18-year development, we establish rigorous product quality system and provide well-established after-sales service. We offer more than 90 standard water chiller models and 120 water chiller models for customization. With cooling capacity ranging from 0.6KW to 30KW, our water chillers are applicable to cool different laser sources,laser processing machines, CNC machines, medical instruments, laboratory equipment and so on.