loading

Why the cooling fan of large format leather laser cutter chiller stops suddenly?

large format leather laser cutter chiller

Below is the cause and solution for the stopped cooling fan of large format leather laser cutter water cooling chiller.

1.The cooling fan of the laser cooling chiller is in bad contact or its cable becomes loose. In this case, check the cable accordingly;

2.The capacitance of the water cooling chiller decreases. In this case, change for a new capacitance;

3.The coil of the cooling fan burns out. In this case, users need to replace the whole cooling fan.

After 19-year development, we establish rigorous product quality system and provide well-established after-sales service. We offer more than 90 standard water chiller models and 120 water chiller models for customization. With cooling capacity ranging from 0.6KW to 30KW, our water chillers are applicable to cool different laser sources,laser processing machines, CNC machines, medical instruments, laboratory equipment and so on.