TEYU high power industrial chiller CW-7800 can satisfy the demanding cooling requirement for CO2 laser cutting system up to 800W. CW-7800 water chiller offers a refrigeration capacity of up to 26kW, temperature stability of ±1℃ and range of 5℃-35℃, and max ambient temperature of 45℃. Modbus-485 communication protocol is supported to enable communication between the chiller and laser machine.

High power industrial chiller CW-7800 has a 170L big stainless steel water tank that is specifically designed for process cooling applications. It allows high water flow rates with low pressure drops and ensures a reliable operation even in demanding applications. Water temperature can be set with an intelligent temperature controller and the water chiller system is monitored for multiple alarms. CW-7800 offers high reliability, energy efficiency and durability, making it the perfect cooling unit for 800W CO2 laser.

    oops...!

    no product data.

    Go to homepage
    Product Introduction
    High Power Industrial Chiller System CW-7800 for CO2 Laser Cutting System

    Model: CW-7800

    Machine Size: 155x80x135cm (L x W x H)

    Warranty: 2 years

    Standard: CE, REACH and RoHS

    Product Parameters
    Model CW-7800ENTY CW-7800FNTY
    Voltage AC 3P 380V AC 3P 380V
    Frequency 50Hz 60Hz
    Current 2.1~24.5A 2.1~22.7A
    Max. power consumption 14.06kW 14.2kW


    Compressor power

    8.26kW 8.5kW
    11.07HP 11.39HP



    Nominal cooling capacity

    88712Btu/h
    26kW
    22354Kcal/h
    Refrigerant R-410A
    Precision ±1℃
    Reducer Capillary
    Pump power 1.1kW 1kW
    Tank capacity 170L
    Inlet and outlet Rp1"
    Max. pump pressure 6.15bar 5.9bar
    Max. pump flow 117L/min 130L/min
    N.W. 277Kg 270Kg
    G.W. 317Kg 310Kg
    Dimension 155x80x135cm (L x W x H)
    Package dimension 170X93X152cm (L x W x H)

    The working current can be different under different working conditions. The above information is for reference only. Please subject to the actual delivered product.

    Product Features

    * Cooling Capacity: 26000W

    * Active cooling

    * Temperature stability: ±1°C

    * Temperature control range: 5°C ~35°C

    * Refrigerant: R-410A

    * Intelligent temperature controller

    * Multiple alarm functions                         

    * RS-485 Modbus communication function

    * High reliability, energy efficiency and durability                                       

    * Easy maintenance and mobility

    * Available in 380V,415V or 460V

    Optional Items

                  

     Heater

     

                   

    Filter

    Product Details
    CO2 Laser Cooling System CW-7800 Intelligent temperature controller
                                           

    Intelligent temperature controller

     

    The temperature controller offers high precision temperature control of ±1°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode. 

    High Power Industrial Chiller System CW-7800 for CO2 Laser Cutting System
                                           

    Easy-to-read water level indicator

     

    The water level indicator has 3 color areas - yellow, green and red.

    Yellow area - high water level.

    Green area - normal water level.

    Red area - low water level.  

    High Power Industrial Chiller System CW-7800 for CO2 Laser Cutting System

                                            Junction Box

     

    Professionally designed by engineers from TEYU chiller manufacturer, easy and stable wiring.

    Ventilation Distance

    High Power Industrial Chiller System CW-7800 Ventilation Distance

    Certificate
    High Power Industrial Chiller System CW-7800 Certificate
    Product Working Principle

    High Power Industrial Chiller System CW-7800 Product Working Principle

    FAQ
    Is TEYU Chiller a trading company or a manufacturer?
    We are professional industrial chiller manufacturer since 2002.
    What is the recommended water used in the industrial water chiller?
    The ideal water should be deionised water, distilled water or purified water.
    How often should I change out the water?
    Generally speaking, the water changing frequency is 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too inferior, the changing frequency is suggested to be 1 month or shorter.
    What is the ideal room temperature for the water chiller?
    The working environment of the industrial water chiller should be well ventilated and the room temperature should not be higher than 45 degree C.
    How to prevent my chiller from freezing?
    For users living in high latitude areas especially in winter, they often face the frozen water problem. To prevent the chiller from freezing, they can add an optional heater or add anti-freezer in the chiller. For detailed use of the anti-freezer, it is suggested to contact our customer support team (service@teyuchiller.com) first.

    We're here for you when you need us.

    Please complete the form to contact us, and we'll be happy to help you.

    Related Products
    no data
    Home       Products          SGS & UL Chiller       Cooling Solution       Company       Resource       Sustainability
    Copyright © 2025 TEYU S&A Chiller | Sitemap    Privacy policy
    Contact us
    email
    Contact customer service
    Contact us
    email
    cancel
    Customer service
    detect